Submittal Sheet

UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ................................
_______
SEER
TOTAL CAPACITY*..................
_______
MBH [kW]
SENSIBLE CAPACITY*............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
_______
°F [°C] WB
POWER INPUT REQUIREMENT ........
_______
kW
(*uses blower motor heat)
HEATING PERFORMANCE
EFFICIENCY ................................
_______
HSPF
TOTAL CAPACITY*..................
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ....
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL............
_______
°F [°C] DB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ......................
____________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 12" [304.8 mm]
ABOVE UNIT 60" [1524 mm]
JOB NAME LOCATION
CONTRACTOR ORDER NO.
ENGINEER UNIT MODEL NO.
SUBMITTED FOR APPROVAL RECORD COIL MODEL NO.
DATE AIR HANDLER MODEL NO.
SUBMITTAL SHEET FOR 15PJL SERIES
1
1
/2 TO 5 NOMINAL TON [5.28 TO 17.58 kW], 15 SEER
HEAT PUMP UNITS
FORM NO. X66-1298 REV. 1
Supersedes Form No. X66-1298
FEATURES FOR 15PJL SERIES HEAT PUMP UNITS
1
1
/2 TO 5 NOMINAL TON [5.28 TO 17.58 kW]
Featuring Industry
Standard R-410A
Refrigerant
(IN CERTAIN MATCHED SYSTEMS)
35" Maximum Unit Height.
Coils constructed with copper tubing and enhanced aluminum fins.
Strong, attractive cabinet—louvered design protects the coil from
damage.
Expansion Valves with Internal Check Valve—Provides for quieter
refrigerant metering.
Enhanced Demand Defrost Control
Factory Installed Low Pressure Control
Non-Cycling Reversing Valve
Hot Gas Muffler
Service Valves
Grille/motor mount for quiet fan operation.
Easily accessible control box.
Bi-Directional Filter Drier (Field Installed)
Certified and rated under A.H.R.I. Standard 240.
U.L listed.
ACCESSORIES/OPTIONS
Optional High Pressure Control (Model No. RXAB-A07) ................
Heat Pump Thermostat Warning Light Kit
(Model No. RXPX-D01)
........................................................
Low Ambient Control (Model No. RXAD-A08)..............................
Outdoor Thermostats (Model No. RXPT-A01, A02, A03 or A04) ......
Heat Pump Monitor (Model No. RXPM-B01) ..............................
Thermostats and Subbases (Available through the
PROSTOCK
®
department)......................................................
Compressor Time Delay Control (Model No. RXMD-B01) ..............
Blower Time Delay Control (Model No. RXMD-C04) RXMD-C04 is
not required if the outdoor unit is matched with a furnace or air
handler from the Manufacturer, or if the furnace or air handler used
has a blower off time delay built-in.
..........................................
Sound Enclosure* ................................................................
Start Components* ..............................................................
*Available through the PROSTOCK
®
department.