Specification Sheet

40
Model Numbers
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Sound
Rating
dB
Indoor
CFM [L/s]
Outdoor
Unit
14AJM
Indoor
Coil and/or
Air Handler
Total
Capacity
BTU/H [kW]
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
EER SEER
49
RCFN-H*4824(RGPE-07?BRQ?) 49,000 [14.4] 36,800 [10.8] 12,300 [3.6] 13.00 16.00 77 1,400 [661]
RCFN-H*4824(RGPE-10?BRM?) 50,000 [14.6] 38,500 [11.3] 11,200 [3.3] 13.00 16.00 77 1,550 [731]
RCFN-H*4824(RGPE-12?ARM?) 50,000 [14.6] 39,000 [11.4] 10,900 [3.2] 13.00 16.00 77 1,625 [767]
RCFN-H*4824(RGPT-07?BRQ?) 49,500 [14.5] 37,400 [11.0] 11,900 [3.5] 13.00 16.00 77 1,450 [684]
RCFN-H*4824(RGPT-10?BRM?) 49,500 [14.5] 37,600 [11.0] 11,900 [3.5] 13.00 16.00 77 1,450 [684]
RCFN-H*4824(RGPT-12?ARM?) 49,000 [14.4] 36,800 [10.8] 12,500 [3.7] 13.00 16.00 77 1,375 [649]
RCFN-H*4824(RGRM-09?ZAJ?) 48,500 [14.2] 36,400 [10.7] 12,300 [3.6] 13.00 15.50 77 1,400 [661]
RCFN-H*4824(RGRM-12?RAJ?) 49,000 [14.4] 37,000 [10.8] 12,100 [3.5] 13.00 16.00 77 1,425 [672]
RCFN-H*4824(RGTM-07?RBG?) 49,500 [14.5] 37,600 [11.0] 11,800 [3.5] 13.00 16.00 77 1,475 [696]
RCFN-H*4824(RGTM-09?ZAJ?) 49,000 [14.4] 36,600 [10.7] 12,300 [3.6] 13.00 16.00 77 1,400 [661]
RCFN-H*4824(RGTM-10?RBJ?) 49,000 [14.4] 37,000 [10.8] 12,100 [3.5] 13.00 16.00 77 1,425 [672]
RCFN-H*4824(RHWB-08WRX60A) 48,000 [14.1] 35,850 [10.5] 12,150 [3.6] 13.00 16.00 77 1,450 [684]
RCFN-H*4824(RHWB-10WRX60A) 48,000 [14.1] 11,700 [3.4] 12,450 [3.6] 13.00 16.00 77 1,400 [661]
RCFN-H*4824(ROCA-070E04) 48,500 [14.2] 36,400 [10.7] 12,300 [3.6] 13.00 15.50 77 1,400 [661]
RCFN-H*4824(ROLA-070E04) 49,000 [14.4] 36,400 [10.7] 12,500 [3.7] 13.00 16.00 77 1,375 [649]
RCFN-H*4824(ROLA-115E05) 49,000 [14.4] 36,800 [10.8] 12,300 [3.6] 13.00 16.00 77 1,400 [661]
RCFN-H*4824+RXMD-C04 49,500 [14.5] 38,500 [11.3] 10,900 [3.2] 12.50 15.50 77 1,600 [755]
RBHP-24(RCHL-48A1) 45,500 [13.3] 32,400 [9.5] 13,100 [3.8] 13.00 16.00 77 1,400 [661]
RCQD-4821(RGFE-09?ZCM?) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 12.50 15.10 77 1,400 [661]
RCQD-4821(RGFE-10?ZCM?) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 12.50 15.10 77 1,425 [672]
RCQD-4821(RGFG-09NZCMS) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 12.50 15.10 77 1,400 [661]
RCQD-4821(RGFG-09EZCMS) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 12.50 15.10 77 1,400 [661]
RCQD-4821(RGFG-10EZCMS) 48,000 [14.1] 36,000 [10.5] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4821(RGFG-10NZCMS) 48,000 [14.1] 36,000 [10.5] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4821(RGJF-09?ZCM?) 48,000 [14.1] 36,200 [10.6] 11,800 [3.5] 13.00 15.50 77 1,400 [661]
RCQD-4821(RGJF-10?ZCM?) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 12.50 15.10 77 1,400 [661]
RCQD-4821(RGPE-07?BRQ?) 48,000 [14.1] 36,400 [10.7] 11,800 [3.5] 13.00 16.00 77 1,400 [661]
RCQD-4821(RGPE-10?BRM?) 48,000 [14.1] 36,400 [10.7] 11,800 [3.5] 13.00 16.00 77 1,400 [661]
RCQD-4821(RGPT-07?AMK?) 47,000 [13.8] 34,900 [10.2] 12,100 [3.5] 12.50 15.10 77 1,325 [625]
RCQD-4821(RGPT-07?BRQ?) 48,500 [14.2] 36,800 [10.8] 11,600 [3.4] 13.00 16.00 77 1,425 [672]
RCQD-4821(RGPT-10?BRM?) 48,500 [14.2] 36,800 [10.8] 11,600 [3.4] 13.00 16.00 77 1,425 [672]
RCQD-4821(RGRM-09?ZAJ?) 47,500 [13.9] 36,000 [10.5] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4821(RGRM-10?ZAJ?) 48,000 [14.1] 36,200 [10.6] 11,600 [3.4] 12.50 15.10 77 1,425 [672]
RCQD-4821(RGTM-07?RBG?) 48,000 [14.1] 35,600 [10.4] 12,300 [3.6] 13.00 16.00 77 1,325 [625]
RCQD-4821(RGTM-09?ZAJ?) 47,500 [13.9] 35,900 [10.5] 11,600 [3.4] 13.00 15.50 77 1,400 [661]
RCQD-4821(RHWB-04WMX36A) 45,500 [13.3] 33,100 [9.7] 12,400 [3.6] 12.50 15.10 77 1,300 [613]
RCQD-4821(RHWB-06WMX48A) 45,500 [13.3] 33,200 [9.7] 12,300 [3.6] 12.50 15.10 77 1,325 [625]
RCQD-4821(ROCA-070E04) 47,500 [13.9] 35,800 [10.5] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4821(ROLA-070E04) 47,500 [13.9] 35,900 [10.5] 11,600 [3.4] 13.00 15.50 77 1,375 [649]
RCQD-4821(ROLA-115E05) 48,500 [14.2] 37,200 [10.9] 11,100 [3.3] 13.00 15.50 77 1,500 [708]
RCQD-4821+RXMD-C04 48,500 [14.2] 37,600 [11.0] 10,800 [3.2] 12.00 14.50 77 1,550 [731]
RCQD-4824(RGFE-09?ZCM?) 47,000 [13.8] 35,200 [10.3] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4824(RGFE-10?ZCM?) 47,500 [13.9] 35,900 [10.5] 11,600 [3.4] 12.50 15.10 77 1,425 [672]
RCQD-4824(RGFE-12?RCM?) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 13.00 15.50 77 1,450 [684]
RCQD-4824(RGFG-09NZCMS) 47,000 [13.8] 35,200 [10.3] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4824(RGFG-09EZCMS) 47,000 [13.8] 35,200 [10.3] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4824(RGFG-10EZCMS) 47,000 [13.8] 35,200 [10.3] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4824(RGFG-10NZCMS) 47,000 [13.8] 35,200 [10.3] 11,800 [3.5] 12.50 15.10 77 1,400 [661]
RCQD-4824(RGFG-12NRCMS) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 13.00 15.50 77 1,450 [684]
RCQD-4824(RGFG-12ERCMS) 47,500 [13.9] 36,100 [10.6] 11,400 [3.3] 13.00 15.50 77 1,450 [684]
Rev.
4/5/13
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling (con’t.)
Air
Performance Data
14AJM Series