Specifications
TM039 Rheem Water Star Service Instructions REV: A
Date of Issue: 02/09
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
4
Specifications
Model
Rated Capacity
(Litres)
T & PR Valve
Rating (kPa)
Maximum Inlet
Pressure (kPa)
T/stat setting
(ºC)
Water Connections
T/stat Type
Element Rating
(w)
Series
Capacity
With ECV
Without
ECV
Inlet
Outlet
T&PR
W81
004
4
1000
680
800
70
RP¾/20
RP½/15
Fixed
800
Preventative Maintenance
It is suggested for peak performance that the water heater be serviced annually.
1. Check for discharge from the T&PR valve. When the element is operating a small
discharge of water may be evident. Direct access to the valve is via the circular plastic
cover at the top of the unit. Operate the valve-easing lever to ensure the valve opens
and resets properly. Always open and close the valve gently. The T&PR valve should
be replaced at 5-yearly intervals.
2. Check for leaks at all tank fittings.
3. Check for signs of excessive corrosion on the water heater jacket.
4. Isolate power to the water heater and check all electrical connections for signs of
overheating due to poor connection.
5. Conduct an insulation test on the water heater. (Refer to page 18)