Anodes (Procedure 7)
1. Remove the access cover and turn gas control knob to pilot position. Note number to which knob was set.
2. Isolate water supply at the stopcock.
3. Relieve pressure through a hot tap or the temperature and pressure relief valve.
4. Remove holding screw from recess in rear of jacket top.
5. Remove jacket top - gently lever top from jacket.
6. Remove flue liner lid using handle provided. Warning: The flue liner lid may be hot, use protective gloves to
prevent burns.
7. Using a 27mm tube or socket spanner remove anodes.
8. Apply thread seal tape to anodes, refit and tighten.
9. Restore water supply and test for leaks.
10. Reapply protective coating (Stove Black or similar) around the anode head to prevent corrosion from flue gases.
11. Apply new seal (part number 225502) to flue liner lid and replace lid.
12. Refit jacket top and screw.
13. Turn gas control to previous setting and refit access cover.
Cleaning Or Replacing Flue Baffle (Procedure 8)
1. Remove the access cover and turn gas control knob to the off position. Note number to which knob was set.
2. Remove holding screw from recess in rear of jacket top.
3. Remove jacket top - gently lever top from jacket.
4. Remove flue liner lid using handle provided.
5. Remove flue baffle.
6. Apply new seal (part number 225502) to flue liner lid before replacing lid.
7. Reassemble in reverse order of above.
8. Refit jacket top and screw.
9. Relight the pilot. Lighting instructions are provided on the access door, follow the instructions carefully.
10. Turn gas control to setting noted in step 1 and refit access cover.
Flue Terminal Assembly (Procedure 9)
It may be necessary to alter the gas supply pipe if replacing the flue terminal on models manufactured prior to June
2001 (see page 5).
1. Isolate gas supply at gas cock.
2. Remove access cover.
3. Disconnect gas line between gas cock and gas control.
4. Remove the 3 holding screws from the flue terminal assembly.
5. Gently remove assembly from the jacket.
6. Reassemble in reverse order of above.
7. Relight the pilot. Lighting instructions are provided on the access door, follow the instructions carefully.
Test for gas leaks using soapy water solution after reconnecting gas supply.