Specifications

Stellar Service Instructions REV: D
Date of Issue: 14/09/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
26
Pilot Assembly (Procedure 4)
1. Remove the gas control and burner assembly. (Refer to procedure 2)
2. Disconnect the pilot feed pipe and thermocouple from the gas control and disconnect the high-tension lead from
the piezo igniter.
3. Remove the screw retaining the pilot assembly to the burner air channel.
4. Reassemble in the reverse order of above.
5. Restore gas supply.
6. Relight the pilot. Lighting instructions are provided on the access door, follow the instructions carefully.
Test for gas leaks using soapy water solution after reconnecting gas supply.
7. Turn gas control to setting noted previously and refit access cover.
Pilot Injector (Procedure 5)
1. Remove the gas control and burner assembly. (Refer to procedure 2)
2. Disconnect the pilot pipe at the pilot assembly and draw the pilot feed pipe from the pilot assembly. Note: The
injector is clipped to the end of the pilot feed pipe and will be removed as the pipe is drawn from the pilot
assembly.
3. Slide the replacement injector over the end of the pilot feed pipe, ensuring the injector skirt slips over and
engages the formed end of the pilot feed pipe, prior to inserting the pilot feed pipe into the pilot assembly. Do not
slide the injector into the pilot assembly and insert the feed pipe after.
4. Carefully insert the injector and pilot feed pipe as an assembly into the pilot assembly, ensuring the injector does
not disengage from the pilot feed pipe, and tighten the retaining nut.
5. Restore gas supply.
6. Relight the pilot. Lighting instructions are provided on the access door, follow the instructions carefully.
Test for gas leaks using soapy water solution after reconnecting gas supply.
7. Turn gas control to setting noted previously and refit access cover.
Main Burner Injector (Procedure 6)
1. Remove the gas control and burner assembly. (Refer to procedure 2)
2. Disconnect the burner feed pipe at the gas control.
3. Remove the retaining clip holding the burner feed pipe to the burner air duct.
4. Hinge the burner feed pipe down to disengage the tongue from the end of the burner air duct.
5. Unscrew the injector from the burner feed pipe.
6. Reassemble in the reverse order of above.
7. Restore gas supply.
8. Relight the pilot. Lighting instructions are provided on the access door, follow the instructions carefully.
Test for gas leaks using soapy water solution after reconnecting gas supply.
9. Turn gas control to setting noted previously and refit access cover.