Specifications

Stellar Service Instructions REV: D
Date of Issue: 14/09/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
12
FAULT FINDING
Attempt to light the pilot
Fault Diagnosis Sequence
Refer to lighting instructions on access cover.
Ensure the correct lighting procedure is followed.
Did
the pilot light
and hold?
1
NO
Turn the gas control knob
to main burner position
number "6".
YES
Pilot Fault
Did
the main burner
light?
2
Main Burner Fault
Water Heater
Operating
Is
the complaint
for leaking?
3
Is
the complaint
insufficient hot
water?
4
Is
the complaint
water too
hot?
Leaking water heater
5
Is
the complaint
noisy operation?
6
NO
NO
Intermittent operation
YES
YES
YES
YES
NO
NO
7YES
Insufficient hot water
Water too hot
Noisy operation
Is
the water
temperature above
60 degrees?
NO
NO
Draw water until the tank
temperature is below 55
degrees
YES
Did
the main burner
light?
YES NO
YES