Specification Sheet
Air
4
Model Number Identification
RHLP Series
Model Number Identification
RHLP—HM2417JA
Design Variation
A = 1st Design
Voltage
A = 115/1/60
J = 208/240/1/60
Cabinet Size
17 = 17.5" [431.8 mm] (600-1200 CFM)
21 = 21" [533.4 mm] (1400-1600 CFM)
24 = 24.5" [609.6 mm] (1600-1800 CFM)
Capacity
24 = 18,000/24,000 BTU/H [5.27/7.03 kW]
36 = 30,000/36,000 BTU/H [8.79/10.55 kW]
48 = 42,000/48,000 BTU/H [12.31/14.06 kW]
HM = A/C or HP Multi-Position
(Vertical Upflow/Horizontal Left is the
factory configuration)
Refrigerant /Metering Device
P = R-410A/R-22/Fixed Orifice
L = Standard Efficiency
(X-13 (ECM) Motor)
Classification
H = Air Handler
Rheem
[ ] Designates Metric Conversions
Available Models at 115V A Voltage
RHLP-HM2417AA
RHLP-HM3617AA
RHLP-HM4821AA
RHLP-HM4824AA
• Supply circuit protective devices may be fuses or
“HACR” type circuit breakers.
• Largest motor load is included in single circuit and
multiple circuit.
• If non-standard fuse size is specified, use the next
larger fuse size.
• J Voltage (230V) single-phase air handler is
designed to be used with single or three phase 230
volt power. In the case of connecting 3-phase
power to the air handler terminal block, bring only
two leads to the terminal block. Cap, insulate and
fully secure the third lead.
• The air handlers are shipped from the factory with
the proper indoor coil installed, and cannot be
ordered without a coil.
• The air handlers do not have an internal filter rack.
An external filter rack or other means of filtration is
required.
Available Models at 208/240V J Voltage
RHLP-HM2417JA
RHLP-HM3617JA
RHLP-HM4821JA
RHLP-HM4824JA