Submittal Sheet

Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
RHEEM
MANUFACTURING
COMPANY
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. 12-05 DC FORM NO. X33-1222
Supersedes Form No. X00-0000
ELECTRICAL CONNECTIONS
MAY EXIT TOP OR EITHER SIDE
HIGH VOLTAGE CONNECTION
7
/8 [22.2 mm],
1
3
/32 [27.8 mm], 1
31
/32 [50 mm] DIA. KNOCKOUTS.
LOW VOLTAGE CONNECTION
5
/8 [15.9 mm] AND
7
/8 [22.2 mm] KNOCKOUT
VAPOR LINE CONNECTION
COPPER (SWEAT)
PRIMARY DRAIN CONNECTION
3
/4 [19.1 mm] FEMALE PIPE THREAD (NPT)
AUXILIARY DRAIN CONNECTION
3
/4 [19.1 mm] FEMALE PIPE THREAD (NPT)
UPFLOW/DOWNFLOW APPLICATION ONLY
LIQUID LINE CONNECTION
COPPER (SWEAT)
AUXILIARY DRAIN CONNECTION
3
/4 [19.1 mm] FEMALE PIPE THREAD (NPT)
HORIZONTAL APPLICATION ONLY
UPFLOW UNIT SHOWN:
UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW,
HORIZONTAL RIGHT OR LEFT AIR SUPPLY.
NOTE: 24 CLEARANCE REQUIRED IN FRONT OF
UNIT FOR FILTER AND COIL MAINTENANCE.
A
W
H
19
1
/2 [495 mm]
RETURN AIR
OPENING
21
11
/16
[551 mm]
10
5
/16
[262 mm]
SUPPLY AIR
Model
Cabinet Size
Return Air
Opening Width
(Inches)
Return Air Opening
Depth/Length
(Inches)
17 16 19
1
/2
21 19
1
/2 19
1
/2
24 23 19
1
/2
Return Air Opening Dimensions
Unit Dimensions
5
15
/16
[151 mm]
4
1
/8
[105 mm]
3
1
/16
[76 mm]
1
3
/16[48 mm]
1
1
/8[29 mm]
1
1
/16
[27 mm]
1
3
/8
[35 mm]
2
13
/16
[71 mm]
5
1
/4
[133 mm]
5
3
/8
[136 mm]
[ ] Designates Metric Conversions
( ) Designates Unit with Double Coil Cabinet
Nominal Cooling
Capacity
Tons
Model
Cabinet
Size
Supply
Duct
“A” In. [mm]
Air Flow
CFM (Nom.) [L/s]
Unit Weight/Shipping Weight (Lbs.) [kg]
Unit With
Coil (Max. KW)
Lo Hi
1
1
/2 & 2
17
16
1
/2 [406]
600 [283] 800 [378] 82/96 [37/44]
2
1
/2 & 3
17
16
1
/2 [406]
1000 [472] 1200 [566] 92/106 [37/48]
3 21 19
1
/2 [495] 1200 [566] 97/112 [44/51]
4 24
23
1
/2 [584]
1600 [755] 162/180 [73/81]
5 24
23
1
/2 [584]
1800 [850] 181/198 [82/90]
Unit
Width
“W” In. [mm]
24
1
/2 [622]
17
1
/2 [445]
17
1
/2 [445]
21
1
/2 [533]
24
1
/2 [622]
Unit
Height
“H” In. [mm]
55
1
/2 [1410]
42
1
/2 [1080]
42
1
/2 [1080]
42
1
/2 [1080]
55
1
/2 [1410]
21
1
/2 [533] 50
1
/2 [1282]3
1
/2 & 4
21
19
1
/2 [495]
1400 [661] 1600 [755] 150/166 [68/75]
Unit Dimensions & Weights
HORIZONTAL ADAPTER KIT
VAPOR LINE
CONNECTION
AUXILIARY HORIZONTAL
DRAIN CONNECTION
PRIMARY DRAIN
CONNECTION
AUXILIARY UPFLOW/DOWNFLOW
DRAIN CONNECTION
LIQUID LINE
CONNECTION
VERTICAL DRAIN PAN