Specification Sheet

Air
Airflow Performance Data
RHSL Series
External Static Pressure—Inches W.C. [kPa]
PSC CFM [L/s] Air Delivery/RPM/Watts—240 Volts
RPM 834
Blower Size/
Motor
HP [W]
# of Speed
-6024
with 30 kW
Heater
870
Motor
Speed
from
Factory
902
Manufacturer
Recommended
Air-Flow Range
(Min/Max) CFM
Motor
Speed
948 968
Watts 560 549 535 476 462
10x10
1/2 HP [373]
2 Speed
High
CFM 1537 [725] 1418 [669] 1334 [630]
RPM
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17]
1072 1077
RPM 838 883 922 959 1001
1085
Model
No.
RHSL
-4221
No Heater
-4221
with 20 kW
Heater
-4821/-4824
No Heater
-3617/3621
with 18 kW
Heater
Watts 446 442 407 386 375
10x8
1/3 HP [249]
2 Speed
-4821/-4824
with 25 kW
Heater
RPM
High
240V
1241/1537 CFM
[586/725 L/s]
High
CFM 1148 [542] 1094 [516] 1033 [487]
Low
CFM 1526 [720] 1474 [696] 1427 [673] 1307 [617]
RPM 1033 1053 1067
1241 [586]
Watts 860 835 820
RPM 886 906
-6024
No Heater
925 959 992
839
865 890 913
Watts 542 524 505 468 431
10x10
1/2 HP [373]
2 Speed
High
CFM
935
1437 [678] 1318 [622] 1234 [582]
RPM 1080 1090 1105
Watts 745 729 713 696 678
High
240V
1225/1500 CFM
[553/678 L/s]
Low
CFM 1456 [687] 1404 [663] 1357 [640] 1237 [584] 1171 [553]
Watts 840 800 785
RPM 878 920 950 981 1007
Watts 785 757 707 667 641
10x10
3/4 HP [559]
2 Speed
High
CFM 1824 [861] 1767 [834] 1653 [780]
RPM 1102 1112 1121
11x11
3/4 HP [559]
2 Speed
High
CFM
High
240V
1572/1824 CFM
[742/861 L/s]
Low
CFM 1741 [822] 1719 [811] 1667 [787] 1628 [768] 1572 [742]
Watts
871 830 770
RPM 945 965 995 1025 1050
Watts 715 685 650 630 610
10x10
3/4 HP [559]
2 Speed
High
CFM 1724 [814] 1667 [787] 1553 [733]
RPM
High
240V
1116
1054/1148 CFM
[497/542 L/s]
Low
CFM 1179 [556] 1151 [543] 1120 [529] 1091 [515] 1054 [497]
1119 1130
1865 [880] 1808 [853] 1754 [828]
Watts 458 445 424
RPM
High
240V
1225/1500 CFM
[709/814 L/s]
Low
CFM 1671 [789] 1649 [778] 1597 [754] 1558 [735] 1502 [709]
Watts
810 780 730
RPM 764 803 838 865 889
Watts 779 763 747 729 708
11x11
3/4 HP [559]
2 Speed
High
CFM 1965 [927] 1908 [900] 1854 [875]
RPM 943 967 977
987 1001 1014
High
240V
1225/1500 CFM
[709/814 L/s]
High
240V
1766/1965 CFM
[833/927 L/s]
Low
CFM 1944 [917] 1912 [902] 1860 [878] 1813 [856] 1766 [833]
Watts
828 799 795
Low
CFM 1844 [870] 1812 [855] 1760 [831] 1713 [808] 1666 [786]
Watts 788 766 744
240V Airflow Performance Data—RHSL (PSC Motor)
Notes: All 208/240V PSC motors have voltage taps for 208 and 240 volts.
All 208/240V PSC motors are shipped on high speed and 240 volts.
• If the application external static is less than 0.5" WC, adjust the motor speed to the low static speed as described below:
• Unplug the black motor wire off the relay on the control board and plug in the red motor wire.
• Replace the cap on the black motor wire.
Voltage change (208/240V motors):
• Move the orange lead to transformer 208V tap from 240V tap. Replace the wire cap on 240V tap.
• Unplug the purple motor wire off the transformer and plug in the yellow motor wire.
• Replace the cap on the purple motor wire.
The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model.
The following formula can be used to calculate the approximate airflow, if a smaller (N kW) than the maximum heater kit is installed.
Approximate Airflow = Airflow without heater - (Airflow without heater - Airflow with maximum heater) x (N kW/maximum heater kW)
[ ] Designates Metric Conversions
9