Unit installation
SOLAR CONTROLLER AND SOLAR MONITOR
14
If the power supply to the solar control unit is on and the green LED is off or the
red LED is flashing, this indicates there may be a fault with the water heater. The
red LED may emit from three to six flashes in each series of flashes. A constant
glow or pulsing of the red LED does not necessarily mean there is a fault with
the system.
Notes:
If the system is in standby mode with the green LED emitting either a constant
glow or slow pulsing flashes (circulator is off) and the solar storage tank is full
of hot water, the red LED may simultaneously emit a constant glow if solar
radiation is still being received by the solar collectors.
This does not indicate a fault. The red LED will go out when the temperature
in the solar collectors decreases.
During periods of high solar radiation and the circulator activates after having
been off (the green LED will emit either a rapid pulse or a series of three
flashes), such as during start up if the solar collectors have not been covered,
it is possible the red LED may simultaneously emit a rapid pulse for a period
of up to ten (10) minutes.
This does not indicate a fault. Refer to “Commissioning” on page 14 for the
possible green and red LED flashing sequence during start up procedure.
If the red LED continues to emit a rapid pulse for longer than ten (10) minutes,
or emits a series of flashes, then count the number of flashes and phone your
nearest Service Department or Accredited Service Agent to arrange for an
inspection.
COMMISSIONING
Refer to the installation instructions supplied with the solar storage tank for the
complete commissioning procedure.
When the electrical supply is switched on to the solar control unit at start up:
If there is no solar gain, the circulator will not activate and the green LED will
emit a slow pulse.
The slow pulse indicates the circulator is not activated and the power to the
solar control unit has been on for less than 48 hours.
If there is solar gain, the circulator activates and the green LED will emit a
series of three (3) flashes.
The three (3) flashes indicate the circulator is operating and power to the solar
control unit has been on for less than 48 hours.