Specifications

TM013 Vulcan Electric Service Instructions REV: D
D.O.I.: 05/09
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
28
Dip Tube
1. Partially drain the water heater. Refer to „Draining the Water Heater‟ procedure on
page 27.
2. Disconnect the hot water line from the outlet of the water heater.
3. Remove the extension fitting.
4. Using a flat blade screwdriver gently split the outer rim at the top and bottom of the dip
tube face and prise the dip tube out of the cylinder fitting.
5. Fit the replacement dip tube into the cylinder fitting ensuring the flat lines up with the
fitting (dip tube facing up) and gently drive the dip tube into the fitting a short distance.
6. Apply thread tape to the extension fitting and refit; this will push the dip tube into the
correct location.
7. Reconnect the plumbing and restore the water supply.
8. Purge air from the system through hot taps.
9. Restore the power supply.
Anode
Elevated temperatures may be present during the draining process.
Personal Protective Equipment should be worn to prevent the risk of
scalding.
1. Isolate the power and water supplies to the water heater.
2. Relieve pressure from the water heater through the T&PR valve or a hot tap.
3. Remove the anode cap.
4. Using a 27mm tube or socket spanner remove the anode.
5. Apply thread seal tape to replacement anode, refit and tighten. Note: It may be
necessary to cut the anode to length prior to fitting. Refer to specifications on page 5
for the correct anode length.
6. Restore water supply and check for leaks.
7. Refit the anode cap.
8. Purge air from the system through hot taps and restore the power supply to the water
heater.