Specifications
TM013 Vulcan Electric Service Instructions REV: D 
D.O.I.: 05/09 
This document is stored and maintained electronically by   Service. All printed copies not bearing this statement in RED are deemed “uncontrolled” 
27 
Component Replacement 
Draining the Water Heater 
Elevated  temperatures  may  be  present  during  the  draining  process. 
Personal  Protective  Equipment  should  be  worn  to  prevent  the  risk  of 
scalding. 
Personal Protective Equipment should be worn when conducting step 2 of 
this procedure to reduce the risk of electric shock. Refer to Rheem Safety 
Procedure on electrical testing. 
1.  Isolate the power and water supplies to the water heater and remove lower access 
cover. 
2.  Relieve pressure from the water heater through T&PR valve or a hot tap. 
3.  Confirm with a multi-meter between each Active and Neutral at the terminal block 
that voltage is not present. 
4.  Disconnect the cold water supply pipe. 
5.  Fit a drain hose to the cold water connection and run the other end to a drain or safe 
location. 
6.  Open the temperature and pressure relief valve to allow air into the system. 
Temperature & Pressure Relief Valve 
Never fit a T&PR valve with a rating higher than that indicated on the water 
heater rating plate. Do not use reconditioned T&PR valves. 
1.  Partially drain the water heater. Refer to „Draining the Water Heater‟ procedure above.  
2.  Remove the drain line from the T&PR valve. 
3.  Unscrew the T&PR valve and remove.  
4.  Confirm the replacement T&PR valve is the correct rating and refit using thread tape.  
5.  Refit the drain line. 
6.  Close the hot tap and restore water supply. 
7.  Check T&PR valve thread for leaks. 
8.  Operate the T&PR valve lever to reset relief drain. 
9.  Purge air from the system through hot taps. 
10. Restore the power supply to the water heater. 










