Specifications
TM013 Vulcan Electric Service Instructions REV: D
D.O.I.: 05/09
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
25
Thermostat Test 1
EWT2 Thermostat
ST22 Thermostat
Using a multimeter on the resistance scale, measure between the terminals indicated
above on the thermostat. The reading should be less than 1 ohm.
Thermostat Test 2
EWT2 Thermostat
ST22 Thermostat
Using a multimeter set on the resistance scale, measure between the terminals indicated
above on the upper thermostat. If the reading is less than 1 ohm the neutral to the top
element is closed.
Thermostat Test 3
EWT2 Thermostat
ST22 Thermostat
Using a multimeter set on the resistance scale, measure between the terminals indicated
above on the upper thermostat. If the reading is less than 1 ohm the neutral to the
bottom element is closed.