Specifications
TM013 Vulcan Electric Service Instructions REV: D 
D.O.I.: 05/09 
This document is stored and maintained electronically by   Service. All printed copies not bearing this statement in RED are deemed “uncontrolled” 
25 
Thermostat Test 1 
EWT2 Thermostat 
ST22 Thermostat 
Using  a  multimeter  on  the  resistance scale, measure  between the  terminals  indicated 
above on the thermostat. The reading should be less than 1 ohm. 
Thermostat Test 2 
EWT2 Thermostat 
ST22 Thermostat 
Using a multimeter set on the resistance scale, measure between the terminals indicated 
above on the upper thermostat. If the reading is less than 1 ohm the neutral to the top 
element is closed. 
Thermostat Test 3 
EWT2 Thermostat 
ST22 Thermostat 
Using a multimeter set on the resistance scale, measure between the terminals indicated 
above  on  the  upper  thermostat.  If  the  reading  is  less  than  1  ohm  the  neutral  to  the 
bottom element is closed. 