Specifications

TM013 Vulcan Electric Service Instructions REV: D
D.O.I.: 05/09
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
24
Component Tests
Terminal Block Test
Single Element
Twin Element
Using a multimeter on the AC voltage scale, measure between each active and neutral
on the terminal block. Normal voltage is 240 volts
ECO Test 1
EWT1 Thermostat
ST12 Thermostat
Using a multimeter on the x1 resistance scale, measure between terminals indicated
above on the thermostat. The reading should be less than 1 ohm.
ECO Test 2
EWT2 Thermostat
ST22 Thermostat
Using a multimeter set on the resistance scale, measure between the terminals indicated
above on the top thermostat. The reading should be less than 1 ohm.