Specifications

TM013 Vulcan Electric Service Instructions REV: D
D.O.I.: 05/09
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
19
Tempering Valve Diagnostic
NO
Normal Operation
Tempering valves are generally set to deliver water at 48 -
50 degrees
Depending on the length of pipe work and insulation to the
fixture(s), water temperature can be lower due to heat loss
NOTE: AS/NZS 3500 Part 4 only requires fixtures used for
ablution purposes to be tempered.
If practical a 2 zone plumbing solution may be offered.
YES
Clean or replace:
Refer to manufacturers instructions for Tempering Valve
YES
Replace Tempering Valve :
Refer to manufacturers instructions for tempering Valve
NO


2 zone plumbing solution
Tempering value diagnostic
Are the filters blocked?
Is the outlet water temp
approx. 48 degrees C?