Specifications
TM013 Vulcan Electric Service Instructions REV: D
D.O.I.: 05/09
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
16
Twin Element – Upper Element
YES
NO
NO
YES
NO
YES
NO
YES
YES
Twin Element Diagnostic
Install the bottom element
correctly and reset the ECO
NO
Replace top thermostat
Break in upper circuit wiring loom.
Locate and repair.
YES
NO Replace top element
Are the top thermostat ECO
contacts closed?
ECO TEST 2
Is the top element installed in
the correct orientation?
Is the tank water 8°C less
than the thermostat
temperature setting?
Does the top element have
the correct resistance?
ELEMENT TEST
Is the neutral contact to the
lower element closed?
THERMOSTAT TEST 3
Is the bottom element
installed in the correct
orientation?
YES
Install the top element correctly
and reset the ECO
NO
Is the neutral contact to the upper
element closes?
THERMOSTAT TEST 2
Twin Element
Lower Element Diagnostic
Replace top thermostat
Replace top thermostat