Specifications
TM013 Vulcan Electric Service Instructions REV: D 
D.O.I.: 05/09 
This document is stored and maintained electronically by   Service. All printed copies not bearing this statement in RED are deemed “uncontrolled” 
14 
Power Supply 
No Hot Water
Power Diagnostic 
Twin Element DiagnosticSingle Element Diagnostic 
YES
Is 240 volts present at the 
terminal block?
TERMINAL BLOCK TEST
Is the water heater connected 
to an off peak tariff?
Is the isolating 
switch turned off?
Is the fuse(s) blown at the 
switch board?
NO
Isolate power and continue with 
following diagnostic procedures.
Electrical Insulation Diagnostic
Possible failure of the off peak relay or 
missed signal from energy supplier.
Continue with diagnosis to confirm 
water heater is operational 
YES
NO
Restore power and advise customer YES
NO
Fault in household electrical 
wiring.
Continue with diagnosis to confirm 
water heater is operational.
NO
YES
Conduct an electrical insulation test.
Refer to the section on „Electrical 
Insulation Testing‟.
Is the reading below 1MΩ?
YES
NO
TWIN ELEMENT MODELS
Complaint may be due to the booster 
circuit also being controlled by the off 
peak relay.
Connect to continuous tariff










