Specifications
TM013 Vulcan Electric Service Instructions REV: D 
D.O.I.: 05/09 
This document is stored and maintained electronically by   Service. All printed copies not bearing this statement in RED are deemed “uncontrolled” 
10 
The new design cylinder element barrels do not have an earthing tab and require the earth 
bond to be connected to the earthing tab on the thermostat clamp (refer to fig. 4). 
When installing an early or new type element on a cylinder barrel that has 
an earth tab, this earth tab must be used (refer to fig.3). 
When  installing  an  early  or  new  type  element  on  a  new  type  cylinder 
barrel that does not have an earth tab, the  earth tab on the thermostat 
clamp must be used (refer to 4). 
Fig.3. 
Cylinder barrel Earth tab 
Fig.4. 
Thermostat clamp Earth tab 
Refer also to Technical Bulletins TB05 019 and TB05 020 
Thermostat changes 
From August 14 2007, the Robertshaw EWT series thermostats  have been replaced by 
the Robertshaw ST series thermostats. This change applies to all electric water heaters. 
It should be noted that although ST series thermostat is a direct replacement for the EWT 
series thermostat, the terminal connections and wiring arrangement is different. Therefore; 
Whenever an EWT series thermostat is replaced with a ST series thermostat 
as  a  spare  part,  each water  heater will  require rewiring  at  the thermostat. 
Refer to wiring diagrams in this service instruction for wiring arrangements 
utilising the new ST series thermostat. 
ST12 Replaces EWT1 
ST22 Replaces EWT2 