Owner`s manual
Direct-Injection Humidifier
5 69-2306—01
About your new thermostatLED light indicators
TheLEDlightpanelonthehumidifierletsyouknowthatthehumidifierisoperatingcorrectly,
whenmaintenanceisneeded,andwhenitissafetoremovethetankforcleaning.Thepushbut-
tonsallowthetanktobedrainedforcleaning,andquicklyreturntooperationwhenthetankis
reattached to the humidifier.
Power indicates the humidifier is plugged in and ready for operation.
Humidifying indicates that steam is being delivered to the home.
Clean Tank: This LED blinks to indicate the humidifier tank is draining
whenyoupresstheEMPTYbutton.Whenthelightisonsolid(notblinking),
the tank is empty and safe to remove for cleaning.
Call Serviceisafaultindicator.CallyourHVACtechniciantoservicethe
humidifier. HVAC technicians: Refer to page 12 for fault identification and
troubleshooting.
Press Reset will blink when power is applied or reapplied (upon initial
installation or after cleaning). This is a stand-by mode to ensure water
lines are hooked up properly before unit resumes operation. This will blink
for 5 minutes before going to system ready. The 5-minute default can be
overriden by the installer by pressing the RESET button.
Press Empty will blink to indicate that the water tank needs cleaning. Push
the EMPTY button to drain the tank for safe removal and cleaning.
Reset ButtonIfthePressResetlightisblinking,presstheRESETbuttonto
overridethe5-minutedelayatstartup.IftheCallServiceLEDison(faultis
present),press/releasetheRESETbuttontoblinkadiagnosticcodeonthe
CallServiceLED.Press/Holdthebuttonfor5secondstoclearallfaultsand
reset“CleanTank”timers.IfthePressEmptyLEDisblinking,press/holdthe
RESET button for 5 seconds to turn off the Press Empty LED and restart the
Clean tank timer.
Empty Button Press and hold for 3 seconds to drain the tank of water for
service. Do this before servicing the tank and internal parts.
POWER
HUMIDIFYING
CLEAN TANK
CALL SERVICE
PRESS RESET
PRESS EMPTY
RESET
EMPTY
SEE LABEL BELOW
!
M24763