Installation guide
Humidification System 
 5 69-2307—01
safeTy PReCauTIons
M24744
duCT mounT InsTallaTIon
Choose a location that has access to a:
• Drainallowingaslopeof1/4in. 
per foot of drain hose.
• Coldwaterline.
• Electricalcircuitratedtoyour
humidifier.
• Verticalsurfacewithadequate
clearances.
1
Model
Required Minimum 
Circuit Capacity
RXIH-AS06A 7 Amps
RXIH-AS09A 10 Amps
RXIH-AS12A 12 Amps
M24745
Install duct nozzle.
2
M24746
Ensureo-ringgasket
is properly seated in 
the groove.
M24894
Insert nozzle and twist clock-
wise to ensure tight seal of 
nozzle to the humidifier.
Continuous 
downslope
If installing the humidifier directly to the supply duct, follow steps on pages 5–6 and 14–18. 
If mounting remote from the duct, follow steps on pages 7–18.
Draining water 
may be hot. 
Ensuredrainout-
let not exposed.
CAUTION 
Hot water temperature above 120°F (49°C) 
can cause burns from scalding.