Installation guide
Installation Guide
69-2307—01 12
M24770
Cut a 1-3/4 in. diameter duct hole, install the provided 
gasket, and slide the remote nozzle up into the duct. 
Secure remote nozzle to duct using #8 self-drilling 
sheet metal screws (4).
6
IMPORTANT:
Run hose continuously uphill. For horizontal runs, 
ensure a slope of 2 in. uphill per foot. Secure hose 
every horizontal foot using clamps (provided).
For long horizontal runs, support the hose by first 
securing a length of 2 x 4 lumber, U-channel, or 
angle iron with the appropriate slope. Then attach 
the hose to the top of this support. If remote hose 
requires downward pitch, refer to pages 7 and 9 for 
instruction.
M24771
Run remote hose from 
the humidifier to the duct 
nozzle location. Up to 20 
ft. of hose can be used.
7
If mounting remotely requires running 
hose through structural barriers (ie. 
wall or ceiling), cut at least a 2-1/8 in. 
hole and slide hose through.
Seal off unconditioned space with a 
grommet (not provided) or caulk.
8
Attach remote hose by sliding over the nozzle 
and adapter. Secure both hose ends with 
clamps (provided).
9
RemoTe mounT InsTallaTIon
Minimum 3 in. clearance 
required from nozzle outlet to 
duct wall.