CARING FOR YOUR WATER HEATER
Water Heater Inspections
Venting System (Direct Vent Only)
The venting system should be inspected annually by
a qualified service technician to ensure all of the vent
sections are secure and airtight�
!
WARNING:
DO NOT operate the water heater if the vent
system shows signs of leaking exhaust.
Leaking exhaust could lead to death, personal
injury, and/or product failure.
Check the air intake and vent outlet for blockage and/or
debris�
Condensate Trap (Direct Vent Only)
!
CAUTION:
DO NOT operate without the condensate trap
connected to the vent and routed to the proper
drain. It could cause the system to malfunction
or fail.
On a regular basis, inspect the condensate trap to ensure
there is enough water in the trap and the condensate is
draining properly
Ensure that condensate is disposed of per local codes
and regulations�
Use Instructions
Outdoor models