Specification Sheet
Air
Performance Data
RP14 Series
16
RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal) furnace with Comfort Control System Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 RGPE-05?BMK? RCF2417STAM 18800 [5.5] 13600 [4.0] 5200 [1.5] 14 11.5 575 [271.4] 17100 [5.0] 3.6 10200 [3.0] 2.34 8.2 7492682
RP1418AJ1 RGPE-07?AMK? RCF2417STAM 19000 [5.6] 13900 [4.1] 5100 [1.5] 14 11.5 625 [295.0] 17000 [5.0] 3.6 10300 [3.0] 2.4 8.2 7492683
RP1424AJ1 RGPE-05?BMK? RCF2417STAM 23400 [6.9] 17000 [5.0] 6400 [1.9] 14 11.5 750 [354.0] 22400 [6.6] 3.5 12400 [3.6] 2.26 8.2 7492692
RP1424AJ1 RGPE-07?AMK? RCF2417STAM 23800 [7.0] 17600 [5.2] 6200 [1.8] 14 11.5 825 [389.4] 22800 [6.7] 3.6 12700 [3.7] 2.34 8.2 7492693
RP1430AJ1 RGPE-07?BRQ? RCF3621STAM 28800 [8.4] 22100 [6.5] 6700 [2.0] 14 11.5 1050 [495.5] 27400 [8.0] 3.54 16500 [4.8] 2.34 8.2 7492706
RP1430AJ1 RGPE-10?BRM? RCF3621STAM 28800 [8.4] 22200 [6.5] 6600 [1.9] 14 11.5 1075 [507.3] 27400 [8.0] 3.54 16500 [4.8] 2.34 8.2 7492707
RP1436AC1 RGPE-07?BRQ? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492715
RP1436AC1 RGPE-10?BRM? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492716
RP1436AJ1 RGPE-07?BRQ? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492722
RP1436AJ1 RGPE-10?BRM? RCF3621STAM 35200 [10.3] 26200 [7.7] 9000 [2.6] 14 11.5 1225 [578.1] 34800 [10.2] 3.7 22400 [6.6] 2.54 8.2 7492723
Performance Data @ AHRI Standard Conditions – Heat Pump (con’t.)
R95T: 95% AFUE single-stage Constant Torque Multipoise Gas Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 R95TA0401317MSA RCF2417STAM 19000 [5.6] 14000 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17200 [5.0] 3.54 10400 [3.0] 2.4 8.2 7492676
RP1430AJ1 R95TA0401317MSA RCF3621STAM 28200 [8.3] 21100 [6.2] 7100 [2.1] 14 11.5 950 [448.4] 27000 [7.9] 3.46 16300 [4.8] 2.3 8.2 7492702
R96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 R96VA0702317MSA RCF2417STAM 19000 [5.6] 14000 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17100 [5.0] 3.54 10400 [3.0] 2.4 8.2 7492677
RP1430AJ1 R96VA1002521MSA RCF3621STAM 28800 [8.4] 22100 [6.5] 6700 [2.0] 14 11.45 1050 [495.5] 27400 [8.0] 3.5 16500 [4.8] 2.3 8.2 7492703
RGFG: 95 Plus Communicating Modulating Upflow Gas Furnace equipped with Confront Control, ECM Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1418AJ1 RGFG-06?MCK? RCF2417STAM 18700 [5.5] 13500 [4.0] 5200 [1.5] 14 11.5 575 [271.4] 17100 [5.0] 3.6 10200 [3.0] 2.34 8.2 7492678
RP1418AJ1 RGFG-07?MCK? RCF2417STAM 19000 [5.6] 14000 [4.1] 5000 [1.5] 14 11.5 650 [306.8] 17100 [5.0] 3.54 10400 [3.0] 2.4 8.2 7492679
[ ] Designates Metric Conversions