Gas Furnaces R962V Endeavor™ Line Classic Plus® Series Gas Furnaces R962V 96% A.F.U.E.† EcoNet® Enabled Heating Stages: Two-Stage Motor Type: Constant CFM Input Rates: 40 to 115 kBTU [11.7 to 33.7 kW] Configuration Options: 4-Way Multi-Position = A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. FORM NO.
Table of Contents R962V Table of Contents Features & Benefits ..................................................................3 Model Number Identification ....................................................4 Physical Data and Specifications .............................................5 Dimensional Data .....................................................................6 Blower Performance Data ........................................................7 Accessories .....................................
Features and Benefits R962V Features and Benefits • PlusOne® Energy Efficiency: ENERGY STAR® certified, featuring 96% AFUE across all model sizes • Two-Stage Heating: Furnace operation mainly stays at low capacity around 60-65%, but will switch to high capacity to deliver stable heat distribution • PlusOne® Diagnostics: With the Rheem Contractor & EcoNet® Apps, built-in EcoNet® & Bluetooth technology makes monitoring, troubleshooting and repairing the product easier than ever before • Constant CFM Motor
Model Number Identification R962V Gas Furnaces R 96 2 V 040 3 A 17 M4 S C A P Brand Furnace Efficiency Stages of Heating Motor Type Heating Input AC Max. Capacity Major Series Width Position NOx Controls Minor Series Option Code R - Rheem 96 - 96% AFUE 2 - Two-Stage V - ECM Variable 040 - 40,000 [11.7 kW] 3 - 3 ton drive A - 1st Design 17 - 17.5" Width M4 - Multi060 - 60,000 [17.6 kW] 5 - 5 ton drive 21 - 21" Width Speed Series 4 Way 070 - 70,000 [20.5 kW] 24 - 24.
Physical Data and Specifications R962V Physical Data and Specifications U.S. and Canadian Models R962V0403 A17M4CAP R962V0603 A17M4SCAP R962V0703 A17M4SCAP R962V0705 A21M4SCAP R962V0855 A21M4SCAP R962V1005 A21M4SCAP R962V1155A 24M4SCAP HIGH FIRE INPUT BTU/HR [kW] ➀ 42,000 [12.31] 56,000 [16.41] 70,000 [20.50] 70,000 [20.50] 84,000 [24.61] 98,000 [28.72] 112,000 [32.82] LOW FIRE INPUT 29,400 [8.61] 39,200 [11.49] 49,000 [14.36] 49,000 [14.36] 58,800 [17.23] 68,600 [20.11] 78,400 [23.
Dimensional Data R962V Multi-Position Application Unit Dimensions (Clearance to Combustibles) [ 6 MODEL R962V LEFT SIDE 040 060 070 070 (wide) 085 100 115 MINIMUM CLEARANCE (IN.) [mm] RIGHT SIDE BACK TOP FRONT VENT SHIP WGTS. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 [25] 1 [25] 1 [25] 1 [25] 1 [25] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 0 0 0 0 0 123.5 [56] 128.0 [58] 132.0 [60] 147.5 [67] 147.5 [67] 0 0 0 0 0 0 1 [25] 1 [25] 2 [51] 2 [51] 0 0 152.0 [69] 165.
Blower Performance Data R962V Blower Performance Data GAS HEATING TARGET CFM [L/s] [ R962V0403 A17M4SCAP R962V0603 A17M4SCAP R962V0703 A17M4SCAP R962V0705 A21M4SCAP R962V0855 A21M4SCAP R962V1005 A21M4SCAP R962V1155 A24M4SCAP Furnace Lo Heat CFM A (factory) Furnace Lo Heat CFM B (side return) Furnace Lo Heat CFM C (Approx. +7°F) Furnace Lo Heat CFM D (Approx.
Accessories R962V For High Altitudes: Vent Termination Kits: = RXGY-E02: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US Only) RXGY-E02A: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US & Canadian) RXGY-E03: Vertical/Horizontal Concentric Vent Termination Kit 3" Pipe (US Only) NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information.
Accessories R962V THE ECONET® SMART THERMOSTAT BUILT-IN WIFI 4.
Notes R962V 10
Notes R962V 11
GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Conditional Unit Replacement (Registration Required) ....................................Ten (10) Years Heat Exchanger ............................................. Limited Lifetime Conditional Parts ..............................................