Specifications
6
TABLE 1
ELECTRICAL AND PHYSICAL DATA – 13 SEER
2.4 ELECTRICAL & PHYSICAL DATA (SEE TABLE 1)
Electrical Physical
Model
Number
13 SEER
3-PHASE
208/230V
Phase
Frequency (Hz)
Voltage (Volts)
Rated Load
Amperes
(RLA)
Compressor
Locked Rotor
Amperes
(LRA)
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM
[L/s]
Refrig.
Per
Circuit
Oz. [g]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Fuse or HACR
Circuit Breaker
Outdoor Coil Weight
Rev. 1/14/2011
36 3-60-208/230 10.4/10.4 73 0.8 14/14 20/20 20/20 13.72 1 2540 90.6 149 157
[1.27] [1199] [2569] [67.6] [71.2]
42 3-60-208/230 13.2/13.2 88 1.2 18/18 25/25 30/30 13.72 1 2540 106 149 157
[1.27] [1199] [3005] [67.6] [71.2]
48 3-60-208/230 13.7/13.7 83.1 1.2 19/19 25/25 30/30 16.39 1 3290 116.1 188 192
[1.52] [1553] [3291] [85.3] [87.1]
60 3-60-208/230 16/16 110 1.2 22/22 30/30 35/35 19.17 1 3380 157.2 223 234
[1.78] [1595] [4457] [101.2] [106.1]
Electrical Physical
Model
Number
13 SEER
3-PHASE
460V
Phase
Frequency (Hz)
Voltage (Volts)
Rated Load
Amperes
(RLA)
Compressor
Locked Rotor
Amperes
(LRA)
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM
[L/s]
Refrig.
Per
Circuit
Oz. [g]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Fuse or HACR
Circuit Breaker
Outdoor Coil Weight
Rev. 1/14/2011
36 3-60-460 5.8/5.8 38 0.35 8/8 15/15 15/15 13.72 1 2540 90.6 149 157
[1.27] [1199] [2569] [67.6] [71.2]
42 3-60-460 6/6 44 0.8 9/9 15/15 15/15 13.72 1 2540 106 149 157
[1.27] [1199] [3005] [67.6] [71.2]
48 3-60-460 6.2/6.2 41 0.8 9/9 15/15 15/15 16.39 1 3290 116.1 188 192
[1.52] [1553] [3291] [85.3] [87.1]
60 3-60-460 7.8/7.8 52 0.8 11/11 15/15 15/15 19.17 1 3380 157.2 223 234
[1.78] [1595] [4457] [101.2] [106.1]
Electrical Physical
Model
Number
13 SEER
3-PHASE
575V
Phase
Frequency (Hz)
Voltage (Volts)
Rated Load
Amperes
(RLA)
Compressor
Locked Rotor
Amperes
(LRA)
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM
[L/s]
Refrig.
Per
Circuit
Oz. [g]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Fuse or HACR
Circuit Breaker
Outdoor Coil Weight
Rev. 1/14/2011
48 3-60-575 4.8/4.8 33 0.8 7/7 15/15 15/15 16.39 1 3290 116.1 188 192
[1.52] [1553] [3291] [85.3] [87.1]
60 3-60-575 5.7/5.7 38.9 0.8 8/8 15/15 15/15 19.17 1 3380 157.2 223 234
[1.78] [1595] [4457] [101.2] [106.1]
NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
Electrical Physical
Model
Number
13 SEER
1-PHASE
Phase
Frequency (Hz)
Voltage (Volts)
Rated Load
Amperes
(RLA)
Compressor
Locked Rotor
Amperes
(LRA)
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM
[L/s]
Refrig.
Per
Circuit
Oz. [g]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Fuse or HACR
Circuit Breaker
Outdoor Coil Weight
Rev. 1/14/2011
18 1-60-208/230 9/9 46 0.6 12/12 15/15 20/20 7.13 1 1415 67.4 120 128
[0.66] [668] [1911] [54.4] [58.1]
24 1-60-208/230 13.5/13.5 58.3 0.6 18/18 25/25 30/30 8.43 1 1665 67.8 121 129
[0.78] [786] [1922] [54.9] [58.5]
30 1-60-208/230 12.8/12.8 64 0.8 17/17 25/25 25/25 8.7 1 2075 75 139 147
[0.81] [979] [2126] [63.1] [66.7]
36 1-60-208/230 16.7/16.7 79 0.8 22/22 30/30 35/35 13.72 1 2540 90.6 149 157
[1.27] [1199] [2569] [67.6] [71.2]
42 1-60-208/230 17.9/17.9 112 1.2 24/24 30/30 40/40 13.72 1 2540 106 149 157
[1.27] [1199] [3005] [67.6] [71.2]
48 1-60-208/230 21.8/21.8 117 1.2 29/29 35/35 50/50 16.39 1 3290 116.1 188 192
[1.52] [1553] [3291] [85.3] [87.1]
60 1-60-208/230 26.4/26.4 134 1.2 35/35 45/45 60/60 19.17 1 3380 157.2 223 234
[1.78] [1595] [4457] [101.2] [106.1]