Submittal Sheet

FORM NO. X33-1440
Supersedes Form No. X33-1285 Rev. 2
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ..............................
_______ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
FEATURES FOR R802V UPFLOW/HORIZONTAL
80% residential Gas Furnace CSA certified
Two stages of operation to save energy and maintain optimal
comfort level.
Variable speed blower motor technology provides ultimate
humidity control quieter sound levels and year round energy
savings
EcoNet enabled HVAC product
3 way multi poise design UF / HZ
PlusOne
Diagnostics — 7 Segment LED all units
PlusOne
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion
resistance and thermal fatigue reliability.
Solid doors provide quiet operation
Solid bottom
Insulated blower compartment
Low profile 34" cabinet ideal for space constrained
installations
Blower shelf design – serviceable in all furnace orientations
Hemmed edges on cabinets and door
1/4 turn door knobs for tool less access
Integrated Control board features dip switches for easy
system set up
QR code for quick access to product information from your
smart phone or tablet
Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.
FIELD INSTALLED ACCESSORIES
External Bottom Filter Rack RXGF-CB ......................................
External Side Filter Rack RXGF-CD ..........................................
Indoor Coil Casing  RXBC-D14A1..............................................
Indoor Coil Casing  RXBC-D17A1..............................................
Indoor Coil Casing  RXBC-D21A1..............................................
Indoor Coil Casing  RXBC-D21B1..............................................
Indoor Coil Casing  RXBC-D24A1..............................................
Solid Bottom Kit  RXGB-D14 ......................................................
Solid Bottom Kit  RXGB-D17 ......................................................
Solid Bottom Kit  RXGB-D21 ......................................................
Solid Bottom Kit  RXGB-D24 ......................................................
EcoNet Control RETST600SYS ................................................
UPFLOW/HORIZONTAL GAS FURNACE
R802V Series
80% A.F.U.E.