Specification Sheet
Air
Dimensional Data
R802V (UF/HZ) Series
6
Upflow Application
MODEL
R802V-
A B C D E F
REDUCED CLEARANCE (IN.) [mm]
SHIP
WGTS.
(LBS.) [kg]
LEFT
SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
050, 075317 17
1
/2 [445] 16
11
/32 [415] 12
3
/8 [314]
➀
15
1
/2 [381] 2
1
/2 [64] 0
3 [76] ➁
0 1 [25] 3 [76]
6 [152] ➂
125 [57]
075421, 100 21
1
/2 [533] 19
27
/32 [504] 14
1
/8 [359]
➀
18
1
/2 [470] 2
1
/2 [64] 0 0 0 1 [25] 3 [76]
6 [152] ➂
140 [64]
125 24
1
/2 [622] 23
11
/32 [593] 15
7
/8 [403]
➀
22
1
/2 [559] 2
1
/2 [64] 0 0 0 1 [25] 3 [76]
6 [152] ➂
150 [68]
NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁ May be 0" [0 mm] with type B vent.
➂ May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 in accordance with local codes.
[ ] Designates Metric Conversions
Dimensional Data: Upflow Model