Specification Sheet

Air
Model Features/Physical Data & Specifications
R802V (UF/HZ) Series
4
MODEL NUMBERS R802V SERIES R802VA050317M*A R802VA075317M*A R802VA075421M*A R802VA100521M*A R802VA125524M*A
High Input-BTU/Hr [kW]
50,000 [15] 75,000 [22] 75,000 [22] 100,000 [29] 125,000 [37]
Heating Capacity BTU/Hr [kW]
40,000 [12] 60,000 [18] 60,000 [18] 80,000 [23] 100,000 [29]
Low Input BTU/Hr [kW]
35,000 [10] 52,500 [15] 52,500 [15] 70,000 [20] 87,500 [25]
Heating Capacity BTU/Hr [kW]
28,000 [8] 42,000 [12] 42,000 [12] 56,000 [16] 70,000 [20]
Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .12 [.029] .15 [.037] .20 [.05]
Blower (D x W) [mm]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
Motor H.P.
Type [W]
1
/2 ECM
[373]
1
/2 ECM
[373]
3
/4 ECM
[560]
3
/4 ECM
[560]
3
/4 ECM
[560]
Motor Full Load Amps 7.7 7.7 9.6 9.6 9.6
Cooling CFM @ Rating Point
[L/s]
1250
[590]
1650
[780]
1800
[850]
1750
[825]
1900
[900]
Max. E.S.P. (In. W.C.) [kPa] 1.0 [.249] 1.0 [.249] 1.0 [.249] 1.0 [.249] 1.0 [.249]
Temperature Rise Range °F
[°C]–High Input
25-55
[13.9-30.6]
25-55
[13.9-30.6]
25-55
[13.9-30.6]
35-65
[19.4-36.1]
35-65
[19.4-36.1]
Temperature Rise Range °F
[°C]–Low Input
20-50
[12.8-29.4]
20-50
[12.8-29.4]
20-50
[12.8-29.4]
30-60
[18.3-35]
30-60
[18.3-35]
Max. Outlet Air Temp. °F
[°C]
155
[68.3]
155
[68.3]
165
[73.8]
180
[82.2]
180
[82.2]
Approx. Shipping Weight (Lbs.)
[kg]
125
[57]
125
[57]
140
[64]
140
[64]
150
[68]
AFUE
80.0% 80.0% 80.0% 80.0% 80.0%
NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is
1
/2" [12 mm] N.P.T.
In accordance with D.O.E. test procedures.
See Conversion Kit Index Form for high altitude derate.
* S = Standard, X = Low Nox
[ ] Designates Metric Conversions
80% residential Gas Furnace CSA certified
Two stages of operation to save energy and maintain optimal
comfort level.
Variable speed blower motor technology provides ultimate
humidity control quieter sound levels and year round energy
savings
EcoNet enabled HVAC product
3 way multi poise design UF / HZ
PlusOne
Diagnostics — 7 Segment LED all units
PlusOne
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion
resistance and thermal fatigue reliability.
Solid doors provide quiet operation
Solid bottom
Insulated blower compartment
Low profile 34" cabinet ideal for space constrained
installations
Blower shelf design serviceable in all furnace orientations
Hemmed edges on cabinets and doors
1/4 turn door knobs for tool less access
Integrated Controls board features dip switches for easy
system set up
QR code for quick access to product information from your
smart phone or tablet
Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.
Model Features