Submittal Sheet

FORM NO. X33-1445
Supersedes Form No. X33-1285 Rev. 2
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ........
_______
MBH [kW]
TOTAL CAPACITY OUTPUT*......
_______
MBH [kW]
DESIGN TEMP. RISE ................
_______
°F [°C] DB
AFUE ..................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ....................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ..................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................
_______
IWG
BLOWER SPEED..............................
_______
RPM
POWER OUTPUT REQUIREMENT ....
_______
BHP
MOTOR RATING ..........................
_______
HP [W]
POWER INPUT REQUIREMENT ..........
_______
kW
ELECTRICAL DATA
POWER SUPPLY ................................
_______ Hz
TOTAL UNIT AMPACITY..................
_______
AMPS
MINIMUM WIRE SIZE ......................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............
_______
AMPS
FEATURES FOR R802V DOWNFLOW
80% residential Gas Furnace CSA certified
Two stages of operation to save energy and maintain optimal
comfort level.
Variable speed blower motor technology provides ultimate
humidity control, quieter sound levels, and year round energy
savings
EcoNet enabled HVAC product
PlusOne
Diagnostics — 7 Segment LED all units
PlusOne
Ignition System – DSI for reliability and longevity
Heat exchanger is removable for improved serviceability.
Aluminized steel construction provides maximum corrosion
resistance and thermal fatigue reliability.
Low profile 34" cabinet ideal for space constrained
installations
Integrated Control board features dip switches for easy
system set up
Insulated blower compartment
QR code for quick access to product information from your
smart phone or tablet
Compatible with single or two stage thermostats. For optimal
performance a two stage thermostat is recommended.
FIELD INSTALLED ACCESSORIES
Filter Rack RXGF-CC ................................................................
Combustible Floor Base RXGC-B17 ........................................
Combustible Floor Base RXGC-B21 ........................................
Combustible Floor Base RXGC-B24 ........................................
EcoNet Control RETST600SYS ................................................
DOWNFLOW GAS FURNACE
R802V Series
80% A.F.U.E.
Input Rates 75 to 125 kBTU [22 to 37 kW]