Specification Sheet

5
Air
Performance Data
RPQL- JEZ Series
Model Numbers
AHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
DOE High Temp.
Outdoor Air
17°F [–8.5°C] DB/
15°F [–9.5°C] WB
DOE Low Temp.
DOE
Region
IV
HSPF
Outdoor
Unit
RPQL-
Indoor
Coil and/or
Air Handler
Total
Capacity
BTU/H
[kW]
Net
Sens.
BTU/H
[kW]
Net
Latent
BTU/H
[kW]
EER SEER
Snd.
Rate
dB
Indoor
CFM
[L/s]
BTU/H
[kW]
COP
BTU/H
[kW]
COP
018JEZ
RHLL-HM2417(RCSL-H*2417)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
650
[307]
17,200
[5.0]
3.96
10,500
[3.1]
2.54 9.00
RCFL-H*2417
18,200
[5.3]
13,900
[4.1]
4,300
[1.3]
11.00 13.50 70
650
[307]
16,600
[4.9]
4.10
9,900
[2.9]
2.58 8.50
RCFL-H*2417(RGFE-06(E,N)MCKS)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.00 70
575
[271]
16,600
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGFE-07(E,N)MCKS)
18,500
[5.4]
14,100
[4.1]
4,400
[1.3]
12.50 15.00 70
600
[283]
16,600
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGFG-06EMCKS)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.00 70
575
[271]
16,600
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGFG-07EMCKS)
18,400
[5.4]
14,000
[4.1]
4,400
[1.3]
12.50 15.00 70
600
[283]
16,700
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGGE-06(E,N)MCKS)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
625
[295]
16,600
[4.9]
3.88
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGGE-07(E,N)MCKS)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.00 70
575
[271]
16,600
[4.9]
3.88
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGJF-06(E,N)MCKS)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
625
[295]
16,600
[4.9]
3.88
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGJF-07(E,N)MCKS)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.00 70
575
[271]
16,600
[4.9]
3.88
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGLE-07(E,N)AMKR)
18,500
[5.4]
14,100
[4.1]
4,400
[1.3]
13.00 15.50 70
600
[283]
16,600
[4.9]
3.90
9,900
[2.9]
2.46 9.00
RCFL-H*2417(RGLT-07(E,N)AMKR)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
675
[319]
16,700
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGLT-07?AMK?)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
675
[319]
16,700
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGPE-05(E,N)BMKR)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.00 70
575
[271]
16,600
[4.9]
3.88
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGPE-07(E,N)AMKR)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
625
[295]
16,600
[4.9]
3.88
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGPT-05(E,N)BMKR)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
12.50 15.00 70
650
[307]
16,700
[4.9]
3.84
10,000
[2.9]
2.42 9.00
RCFL-H*2417(RGPT-05?BMK?)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
12.50 15.00 70
650
[307]
16,700
[4.9]
3.84
10,000
[2.9]
2.42 9.00
RCFL-H*2417(RGPT-07(E,N)AMKR)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
625
[295]
16,700
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGPT-07?AMK?)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
625
[295]
16,700
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGRM-04(E,N)MAES)
18,300
[5.4]
13,800
[4.0]
4,500
[1.3]
12.50 15.00 70
575
[271]
16,700
[4.9]
3.84
9,900
[2.9]
2.42 9.00
RCFL-H*2417(RGRM-06(E,N)MAES)
18,400
[5.4]
14,000
[4.1]
4,400
[1.3]
12.50 15.00 70
600
[283]
16,700
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RCFL-H*2417(RGRM-07(E,N)MAES)
18,600
[5.4]
14,300
[4.2]
4,300
[1.3]
12.50 15.00 70
625
[295]
16,800
[4.9]
3.80
10,000
[2.9]
2.40 8.50
RCFL-H*2417(RGTM-06(E,N)MAES)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
625
[295]
16,700
[4.9]
3.84
9,900
[2.9]
2.42 9.00
RCFL-H*2417(ROCA-070E03)
18,500
[5.4]
14,100
[4.1]
4,400
[1.3]
13.00 15.50 70
600
[283]
16,600
[4.9]
3.88
9,900
[2.9]
2.44 9.00
RCFL-H*2417(ROLA-070E03)
18,400
[5.4]
14,000
[4.1]
4,400
[1.3]
12.50 15.00 70
600
[283]
16,700
[4.9]
3.84
9,900
[2.9]
2.42 9.00
RHKL-HM2417(RCSL-H*2417)
18,700
[5.5]
14,400
[4.2]
4,300
[1.3]
13.00 15.50 70
650
[307]
16,700
[4.9]
3.86
9,900
[2.9]
2.44 9.00
RHSL-HM1817(RCSL-H*2417)
18,100
[5.3]
13,700
[4.0]
4,400
[1.3]
11.50 14.00 70
600
[283]
17,000
[5.0]
3.64
10,300
[3.0]
2.32 8.50
Rev.
1/7/2013
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling