Submittal Sheet
UPFLOW MODELS
THE RXGR-C24B MAY ONLY BE INSTALLED
ON REAR AND LEFT SIDES.
RETURN AIR
CABINETS
A
IN. [mm]
B
IN. [mm]
FILTER SIZE
IN. [mm]
RXGR-C17B 17
1
/2 [445] 16
11
/32 [415] (2) 12 x 16 [305 x 406]
RXGR-C21B 21 [533] 19
27
/32 [504] (2) 20 x 16 [508 x 406]
RXGR-C24B 24
1
/2 [622] 23
11
/32 [593] (2) 24 x 16 [610 x 406]
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS
FACING UPWARDS.
MODEL
RGPE-
A B C D E
REDUCED CLEARANCES (IN.) [mm]
05, 07A
17
1
/2 [445] 16
11
/32 [415] 12
3
/8 [314]
➀
15 [381]
0
3 [76] ➁
0 1 [25] 3 [76]
6 [152] ➂
LEFT
SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
SHIP. WGTS.
(LBS.) [Kg]
07B, 10
21 [533] 19
27
/32 [504] 14
1
/8 [359]
➀
18
1
/2 [470]
0 0 0 1 [25] 3 [76]
6 [152]
➂
120 [54.4]
110 [49.9]
12
24
1
/2 [622] 23
11
/32 [593] 15
7
/8 [403]
➀
22 [559]
0 0 0 1 [25] 3 [76]
6 [152]
➂
140 [63.5]
F
2
1
/2 [64]
2
1
/2 [64]
2
1
/2 [64]
HORIZONTAL MODELS
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 4-10 DC FORM NO. X33-1305
Supersedes Form No. X33-1305
NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁ May be 0" [0 mm] with type B vent.
➂ May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
UPFLOW DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
MODEL
RGPE-
A B C D E
REDUCED CLEARANCES (IN.) [mm]
05, 07A 17
1
/
2 [445]
16
11
/
32 [415]
12
3
/
8 [314]
➀
15
1
/
2 [381]
0
3 [76] ➁
0 1 [25] 3 [76]
6 [152] ➂
LEFT
SIDE
RIGHT
SIDE
BACK TOP FRONT VENT
SHIP. WGTS.
(LBS.) [Kg]
105 [47.6]
07B, 10 21
1
/2 [533] 19
27
/32 [504] 14
1
/8 [359]
➀
18
1
/2 [470] 0 0 0 1 [25] 3 [76]
6 [152] ➂
120 [54.4]
12
24
1
/2 [622] 23
11
/32 [593] 15
7
/8 [403]
➀
22
1
/2 [559]
0 0 0 1 [25] 3 [76]
6 [152] ➂
140 [63.5]
F
2
1
/
2 [64]
2
1
/2 [64]
2
1
/2 [64]
NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.
➁ May be 0" [0 mm] with type B vent.
➂ May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes.
[ ] Designates Metric Conversions
HORIZONTAL DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
NOTE: In horizontal configuration, return air cutout is not permitted.