Submittal Sheet

JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
SUBMITTAL SHEET FOR RGPE- TWO-STAGE SUPER QUIET 80
COMMUNICATING UPFLOW/HORIZONTAL GAS FURNACES
EQUIPPED WITH THE COMFORT CONTROL
2
SYSTEM AND
CONTOUR COMFORT CONTROL
®
ECM Equipped Models with Input Rates from
50,000 to 125,000 BTU/HR [15 to 37 kW].
FEATURES FOR RGPE-
The Comfort Control
2
System™ provides over 28 on-board diagnostics and
fault history codes by detecting system and electrical problems. “Call for
Service” alert notification is sent to the thermostat to alert the homeowner of
required service.
Serial Communication Enhanced – When installed with a Serial Communicating
Condensing Unit and user interface control ((-)HC-TST550CMMS) 500 Series
thermostat this unit offers 4 or 2 wire installation, auto-configuration, and diagnostic
messaging with full communicating capability.
Patented Heat Exchanger, constructed of both stainless and aluminized steel
for the maximum in corrosion resistance.
Low profile “34 inch” [864 mm] design is lighter and easier to handle, and leaves
room for optional equipment.
Energy efficient and quiet ECM 2+ communicating motor.
Improves cooling efficiency when matched with rated condensing unit and coil.
Constant CFM.
Seven segment LED for system diagnostics.
Diagnostic history for troubleshooting.
Dip switch settings for selectable cooling airflow.
On-demand dehumidification terminal for improved comfort in cooling mode.
Convertible from upflow to horizontal left or right.
Left or right side gas and electric inlet connections.
All models equipped with flame sensor feature, an integrated board with
humidifier and electronic air cleaner hookups.
Insulated blower compartment, a slow-open gas valve, a specially designed
draft inducer motor and blower motor make it one of the quietest furnaces on
the market today.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Easy door removal and replacement.
Compatible with single or two-stage thermostat. (For optimal performance, two-
stage thermostat recommended.)
A variety of cooling coils and plenums designed to use with Super Quiet 80
Two
Stage gas furnaces are available as optional accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test
procedures.
FIELD INSTALLED ACCESSORIES:
Fossil Fuel Kit: RXPF-F01 and F02 ..................................................................
External Bottom Filter Rack: RXGF-CB ............................................................
External Side Return Filter Rack: RXGF-CA ....................................................
Return Air Cabinets: RXGR-CB ........................................................................
Solid Bottom Kit: (RXGB-D17, 21, 24) ..............................................................
Internal Filter Rack for Bottom or Side Return RXGF-DA ................................
Chimney Adapter: RXGW-B01 ..........................................................................
Thermostats ......................................................................................................
Supply Air Sensor ..............................................................................................
Annual Fuel Utilization Efficiency - AFUE
THIS MODEL
ENER UIDE
97%78%
HIGH
MID
82% 88%
80.0%
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY......................
____________ Hz
UNIT AMPACITY ..........................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
FORM NO. X33-1305
Supersedes Form No. X33-1305