Submittal Sheet

FEATURES FOR RGLE-
The Comfort Control
2
System™ provides over 28 on-board diagnostics and
fault history codes by detecting system and electrical problems. “Call for
Service” alert notification is sent to the thermostat to alert the homeowner of
required service.
Serial Communication Enhanced – When installed with a Serial Communicating
Condensing Unit and user interface control ((-)HC-TST550CMMS) 500 Series
thermostat this unit offers 4 or 2 wire installation, auto-configuration, and
diagnostic messaging with full communicating capability.
Patented heat exchanger, constructed of both stainless and aluminized steel
for the maximum in corrosion resistance.
Low profile “34 inch” [864 mm] design is lighter and easier to handle, and
leaves room for optional equipment.
Energy efficient and quiet ECM 2+ communicating motor.
Improves cooling efficiency when matched with rated condensing unit and coil.
Constant CFM.
Seven segment LED for system diagnostics.
Diagnostic history for troubleshooting.
Dip switch settings for selectable cooling airflow.
On-demand dehumidification terminal for improved comfort in cooling mode.
Left or right side gas and electric inlet connections.
All models feature an integrated board with humidifier and electronic air cleaner
hookups.
Insulated blower compartment, a slow-open gas valve, specially designed draft
inducer motor and blower motor make it one of the quietest furnaces on the
market today.
Pre-paint galvanized steel cabinet.
Easy door removal and replacement.
Molded permanent filter.
Compatible with single or two-stage thermostat. (For optimal performance, two-
stage thermostat recommended.)
A variety of cooling coils and plenums designed to use with Super Quiet 80
Two
Stage Downflow gas furnaces are available as optional accessories.
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test
procedures.
FIELD INSTALLED ACCESSORIES
Fossil Fuel Kit (RXPF-F01 and F02) ................................................................
Filter Rack (RXGF-CCM) ..................................................................................
Combustible Floor Base (RXGC-B17, 21, 24) ..................................................
Supply Air Sensor ..............................................................................................
Chimney Adapter: RXGW-B01 ..........................................................................
Thermostats ......................................................................................................
FORM NO. X33-1304
Supersedes Form No. X33-1304
SUBMITTAL SHEET FOR SUPER QUIET 80
TWO STAGE
COMMUNICATING DOWNFLOW GAS FURNACES EQUIPPED
WITH THE COMFORT CONTROL
2
SYSTEM
ECM Equipped Models with Input Rates from 75,000 to 125,000
BTU/HR [22 to 37 kW]
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ......
_______
MBH [kW]
TOTAL CAPACITY OUTPUT* ..
_______
MBH [kW]
DESIGN TEMP. RISE ..............
_______
°F [°C] DB
AFUE ................................................
_______
%
CALIFORNIA SEASONAL
EFFICIENCY ..................................
_______
%
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT......................................
_______
IWG
BLOWER SPEED ..........................
_______
RPM
POWER OUTPUT REQUIREMENT ..
_______
BHP
MOTOR RATING ........................
_______
HP [W]
POWER INPUT REQUIREMENT ........
_______
kW
ELECTRICAL DATA
POWER SUPPLY........................
___________ Hz
TOTAL UNIT AMPACITY................
_______
AMPS
MINIMUM WIRE SIZE ....................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ..........
_______
AMPS
CLEARANCES
FRONT SIDE 3" [76.2 mm]
RIGHT SIDE 3" [76.2 mm]
LEFT SIDE 0" [0 mm]
TOP 1" [25.4 mm]
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE