Operating instructions

A. Outdoor Water Heater Location
❑ Outdoor water heaters must be installed outdoors.
❑ Protected from freezing temperatures.
❑ Proper clearance from combustible surfaces observed
.
❑ Sufficient fresh air supply for proper operation of
water heater.
❑ Air supply free of corrosive elements and
flammable vapors.
❑ Provisions made to protect area from water damage.
❑ Sufficient room to service heater.
❑ Combustible materials, such as clothing, cleaning
materials, rags, etc. clear of the heater and
vent piping.
❑ Water heater is properly attached to the wall.
B. Water Supply
❑ Water supply has sufficient pressure.
❑ Air purged from water heater and piping.
❑ Water connections tight and free of leaks.
❑ Water filter is clean and in place.
❑ Materials used are as instructed in this manual.
❑ Water pipes are insulated and protected from
freezing.
C. Gas Supply
❑ Gas type matches rating plate.
❑ Gas supply pressure is sufficient for the water heater.
❑ Gas line equipped with shut-off valve, union and
sediment trap.
❑ Approved pipe joint compound used.
❑ Soap and water solution used to check all connections
and fittings for possible gas leak.
❑ Gas Company inspected installation (if required).
D. Relief Valve
❑ Pressure Relief Valve properly installed and discharge
line run to open drain.
❑ Discharge line protected from freezing.
E. Electrical Wiring
❑ Voltage matches rating plate.
❑ Water heater is properly grounded.
❑ Supply cord and/or wiring meets all local codes.
Installation Check List
20
ap14557-1 (09-08).indd 20 9/17/2008 3:22:04 PM