Test 7
Ensure power is isolated before
conducting test
Using a multimeter on the x1 resistance
scale, measure between terminals 2T
and 4L of the thermostat.
Normal resistance for the heating unit is:
1.2kW: 43-53 ohms 1.5kW: 35-42 ohms
1.8kW: 29-35 ohms 2.4kW: 22-26 ohms
3.0kW: 17-21 ohms 3.6kW: 15-17 ohms
4.8kW: 11-13 ohms 6.0kW: 9-11 ohms
Test 8
Ensure power is isolated before
conducting test
Using a multimeter on the x1 resistance
scale, measure between active and
neutral on the terminal block.
Normal resistance when the thermostat
contacts are closed is:
1.2kW: 43-53 ohms 1.5kW: 35-42 ohms
1.8kW: 29-35 ohms 2.4kW: 22-26 ohms
3.0kW: 17-21 ohms 3.6kW: 15-17 ohms
4.8kW: 11-13 ohms 6.0kW: 9-11 ohms
Test 9
Live equipment Personal
Protective Equipment should be
worn when conducting this test.
Using a multimeter on the AC voltage
scale, measure between each active and
the neutral on the terminal block.
Normal voltage is 240 volts