Technical data
INSTALLATION
9
Storage tank capacity
litres
325
410
Boost capacity 1.8 kW
litres
100
-
2.4 kW*, 3.6 kW*
litres
180
200
Dimensions A
mm
1631
1842
B
mm
863
931
C
mm
638
686
D
mm
1317
1479
E
mm
114
127
F
mm
162
650
H
deg
32
30
K
mm
619
686
Weight tank empty
kg
88
112
Weight heat pump
kg
42
42
Weight system empty
kg
130
154
Weight system full
kg
455
564
Heat pump module model no
180550 (R)
Maximum rated power input
watts
3600
Rated heat pump power input
watts
800
Booster element ratings
kW
1.8, 2.4, 3.6
Refrigerant type
R134a
Refrigerant circuit pressure
kPa
3000
* The boost capacity of a 2.4 kW or 3.6 kW low watts density heating unit if used is
100 litres (325 litre storage tank) or 125 litres (410 litre storage tank).
Technical data is subject to change.