Technical data
INSTALLATION 
9 
Storage tank capacity 
litres 
325 
410 
Boost capacity  1.8 kW 
litres 
100 
- 
  2.4 kW*, 3.6 kW* 
litres 
180 
200 
Dimensions  A 
mm 
1631 
1842 
  B 
mm 
863 
931 
  C 
mm 
638 
686 
  D 
mm 
1317 
1479 
  E 
mm 
114 
127 
  F 
mm 
162 
650 
  H 
deg 
32 
30 
  K 
mm 
619 
686 
Weight tank  empty 
kg 
88 
112 
Weight heat pump 
kg 
42 
42 
Weight system  empty 
kg 
130 
154 
Weight system  full 
kg 
455 
564 
Heat pump module model no 
180550 (R) 
Maximum rated power input 
watts 
3600 
Rated heat pump power input 
watts 
800 
Booster element ratings 
kW 
1.8, 2.4, 3.6 
Refrigerant type 
R134a 
Refrigerant circuit pressure 
kPa 
3000 
*  The  boost capacity  of  a  2.4 kW or  3.6 kW  low  watts  density  heating  unit  if  used  is 
100 litres (325 litre storage tank) or 125 litres (410 litre storage tank). 
Technical data is subject to change. 