Technical data
WATER SUPPLIES 
33 
CHLORIDE AND PH 
Where the chloride level exceeds 250 mg/L the manufacturer‟s  warranty does 
not apply to  the water  heater.  In a  high  chloride water supply,  the water  can 
corrode stainless steel parts and cause them to fail. 
Where the pH is less than 6.0 the  manufacturer‟s warranty does not apply to 
the water heater. pH is a measure of whether the water is alkaline or acid. In an 
acidic water supply, the water can attack stainless steel parts and cause them 
to fail. 
Water with a pH less than 6.0 may be treated to raise the pH. The water supply 
from a rainwater tank in a metropolitan area is likely to be corrosive due to the 
dissolution of atmospheric contaminants. 
SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY 
The water heater, including this heat pump module, is not suitable for certain 
water  chemistries.  Those  chemistries  are  listed  below.  If  the  water  heater  is 
connected at any time to a water supply with the following water chemistry, the 
manufacturer‟s warranty will not cover any resultant faults: 
Water Chemistry 
Saturation Index (SI) < -1.0 
Saturation Index (SI) > +0.4 
Chloride > 250 mg/L 
pH < 6.0 
Refer  to  “Water  Supplies”  in  the  Owner‟s  Guide  and  Installation  Instructions 
supplied with the storage tank for the complete water supply statement. 