Technical data
26 
CONNECTIONS – ELECTRICAL 
The power supply to the water heater must not be switched on until the 
water  heater  is  filled  with  water  and  a  satisfactory  megger  reading  is 
obtained. 
MEGGER READING 
When  a  megger  test  is  conducted on  this  water heater,  then  the  following 
should be noted. 
  Warning:  This  water  heater  contains  electronic  equipment  and  500 V 
insulation tests must only be conducted between active and earth and between 
neutral and earth. An active to neutral test WILL damage the electronics. 
An  insulation  test  result  of  between  100 KΩ  and  660 KΩ  for  this  water 
heater is normal. 
Typically  the  insulation  resistance  between  live  and  earthed  parts  of  an 
electrical  installation  should  not  be  less  than  1 MΩ.  However 
AS/NZS 3000:2000 clause 6.3.3.3.2 „Results‟ states: 
“The value of 1 MΩ may be reduced to: 
  0.01 MΩ for sheathed heating elements or appliances; or 
  a value permitted in the Standard applicable to electrical equipment.” 
This model water heater is categorised as a „stationary class 1 motor operated 
appliance‟  and  has  been  tested  to  AS/NZS 3350.1:2002  clause 16  „Leakage 
current  and  electric  strength‟  and  has  passed  the  requirements  of  this 
Standard. Therefore, this model water heater complies with the condition stated 
in AS/NZS 3000:2000 clause 6.3.3.3.2 (b). 
ELECTRICAL CONNECTION 
All  electrical  work  and  permanent  wiring  must  be  carried  out  by  a  qualified 
person  and  in  accordance  with  the  Wiring  Rules  AS/NZS 3000  and  all  local 
codes and regulatory authority requirements. 
This water  heater  is  recommended  for connection  to a  minimum 16 hour per 
day  power  supply  for  a  325 litre  storage  tank  and  a  24 hour  per  day  power 
supply for a 410 litre storage tank. 