Technical data

HEAT PUMP AND TANK ASSEMBLY
15
4. Mains Power Connection: Connect the mains power supply wiring to the
terminal block and earth connection inside of the lower front cover.
Secure the conduit to the side of the storage tank with a saddle
clamp.
The saddle clamp must be positioned over the pilot holes provided,
otherwise the conduit will interfere with the heat pump module
installation.
Refer to “Connections Electrical” on page 26.
Note: The power supply to the water heater must not be switched on until
the installation is complete, the water heater is filled with water and a
satisfactory megger reading is obtained.
Step 4
Connect wiring and secure conduit with saddle clamp