Technical data
HEAT PUMP AND TANK ASSEMBLY
15
4. Mains Power Connection: Connect the mains power supply wiring to the
terminal block and earth connection inside of the lower front cover.
Secure the conduit to the side of the storage tank with a saddle
clamp.
The saddle clamp must be positioned over the pilot holes provided,
otherwise the conduit will interfere with the heat pump module
installation.
Refer to “Connections – Electrical” on page 26.
Note: The power supply to the water heater must not be switched on until
the installation is complete, the water heater is filled with water and a
satisfactory megger reading is obtained.
Step 4
Connect wiring and secure conduit with saddle clamp