Technical data
11 
HEAT PUMP AND TANK ASSEMBLY 
STORAGE TANK AND HEAT PUMP MODULE 
The heat pump water heater is made of two main components, the storage tank 
and the heat pump module. For transport and handling (weight) purposes both 
items are shipped separately and designed to be assembled at the installation 
site.  The  water  heater  must  not  be  operated  until  both  components  are 
assembled. 
The heat pump storage tank and module must be installed on a level slab or 
solid base of a minimum 900 mm wide x 650 mm deep. The heat pump module 
must be fully supported by the level slab or solid base. 
HEAT PUMP MODULE 
The heat  pump module is shipped in a box  containing two hand holes to 
facilitate  easy handling and  lifting.  The  heat pump  module  is  to be  mounted 
against the side of the storage tank and  must be fully supported by the level 
slab or solid base. 
CAUTION: The heat pump module weighs approximately 42 kg. Use the hand 
holes  provided  in  the sides of the packaging.  Good lifting practice should be 
followed. 
There are two  flexible hoses provided  inside the  heat pump module.  The 
flexible hoses are to be withdrawn from the module and fixed to the two water 
fittings on the heat pump storage tank, during the assembly procedure. 
There are two connection points located on the underside of the control box in 
the heat pump module to which the power cable and tank sensor cable from 
the heat pump storage tank are connected, during the assembly procedure. 
STORAGE TANK 
The heat pump storage tank and module must be installed on a level slab or 
solid  base  of  a  minimum  900 mm wide  x  650 mm deep. The storage tank  is 
designed to receive the heat pump module. 
There  are  two  water fittings  located  at  the  side  of  the  storage  tank to  which 
flexible hoses from the heat pump module are connected, during the assembly 
procedure. 
A power cable and a tank sensor cable are provided behind the lower cover of 
the storage tank. These are to be withdrawn from behind the front cover and 
connected  to  the  control  box  in  the  heat  pump  module  during  the  assembly 
procedure. 