Specification Sheet
Air
Airflow Performance Data
RHLL Series
9
External Static Pressure—Inches W.C. [kPa]
PSC CFM [L/s] Air Delivery/RPM/Watts—115/208/240 Volts
RPM 637
Blower Size/
Motor
HP [W]
# of Speed
692
Tonnage
Application
746
Manufacturer
Recommended
Air-Flow Range
(Min/Max) CFM
Motor
Speed
801 847 — —
Watts 130 142 153 165 176 — —
10x10
3/4 HP [559]
5 Speed
3
CFM — — — — 1103 1059 1000
RPM
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17]
— — — — 917 957 1001
Model
No.
RHLL
-3821
No Heater
-3821
with 18 kW
Heater
-3821
No Heater
-3821
with 18 kW
Heater
2.5 Ton
854/1103 CFM
[403/521 L/s]
2
CFM 1073 [506] 1016 [479] 963 [454] 906 [428] 854 [403] — —
Watts — — — — 262 271 285
RPM 678 734 791 844 883 — —
Watts 141 155 158 171 182 — —
10x10
3/4 HP [559]
5 Speed
3
CFM — — — — 1016 961 904
RPM — — — — 939 968 1015
2.5 Ton
828/1016 CFM
[391/479 L/s]
2
CFM 1044 [493] 988 [466] 936 [442] 880 [415] 828 [391] — —
Watts — — — — 233 243 265
RPM 724 761 814 868 900 — —
Watts 198 208 222 237 245 — —
10x10
3/4 HP [559]
5 Speed
5
CFM — — — — 1288 1244 1200
RPM — — — — 974 1012 1044
3 Ton
1070/1288 CFM
[505/608 L/s]
4
CFM 1264 [597] 1223 [577] 1171 [553] 1112 [525] 1070 [505] — —
Watts — — — — 345 362 371
RPM 759 794 845 915 933 — —
Watts 219 215 227 251 261
10x10
3/4 HP [559]
5 Speed
5
CFM — — — — 1257 1213 1169
RPM — — — — 1020 1023 1054
3 Ton
1042/1257 CFM
[492/593 L/s]
4
CFM 1233 [582] 1193 [563] 1142 [539] 1084 [512] 1042 [492] — —
Watts — — — — 355 368 376
Motor
Speed
From
Factory
4
4
4
4
Notes: X-13 (ECM) motor speed changes.
All X-13 (ECM) motors have 5 speed tabs. Speed tab 1 is for continuous fan. Speed tab 2 (low static) and Speed tab 3 (high static) are for lower tonnage. Speed tab 4
(low static) and Speed tab 5 (high static) are for higher tonnage.
X-13 (ECM) air handlers are always shipped from factory at Speed tab 5, except for -4824, which is set at Speed tab 3. For instance, RHLL-HM2417JA is always
shipped at high static 2-ton airflow (Speed tab 5). To change to 1.5-ton airflow, move the blue wire to Speed tab 2 or 3 on the X-13 (ECM) motor.
The low static Speed tab 2 (lower tonnage) and 4 (higher tonnage) are used for external static below 0.5" WC. The high static Speed tab 3 (lower tonnage) and 5
(higher tonnage) are used for external static exceeding 0.5" WC. Move the blue wire to the appropriate Speed tab as required by the application needs.
• The airflow for continuous fan (Speed tab 1) is always set at 50% of the Speed tab 4.
• The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model.
• The following formula can be used to calculate the approximate airflow, if a smaller (N kW) than the maximum heater kit is installed.
Approximate Airflow = Airflow without heater – (Airflow without heater – Airflow with maximum heater) x (N kW/maximum heater kW)
[ ] Designates Metric Conversions
115V/208V/240V/480V Airflow Performance Data—RHLL (X-13 (ECM) Motor) (con’t.)