Air Air Handlers RF1T/RF1P Series Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.
Air Table of Contents RF1T/RF1P Series TABLE OF CONTENTS Engineering Features ......................................................................................3 Model Number Identification ............................................................................4 Dimensional Data ........................................................................................5-6 Airflow Performance Data ............................................................................7-9 Piston Sizing Chart ....
Air Engineering Features RF1T/RF1P Series Engineering Features RF1T/RF1P- Series • The most compact unit design available, all standard heat air handler models only 36" [915 mm]. • Rugged wall steel cabinet construction, designed for added strength and versatility. • 1.0" foil faced insulation for excellent thermal and sound performance. • Four leg blower motor mount. • Traditional open wire element design for heat applications.
Air Model Number Identification RF1T/RF1P Series Model Number Identification R F Available Models RF1P1821SPANJAB03 1 T 24 21 S P A N J A N 00 *** RF1P1821SPANJAB05 Option Code Blank = None RF1P1821SPANJAB08 Factory Heat 00 = NO HEAT 03 = 3 kW 05 = 5 kW 08 = 8 kW 10 = 10 kW RF1P2421SPANJAB03 Disconnect B = Breaker N = None RF1P2421SPANJAB05 RF1P2421SPANJAB08 RF1P2421SPANJAB10 RF1P2421SPANJAN00 RF1P3024SPANJAB03 RF1P3024SPANJAB05 Minor Series A = First RF1P3024SPANJAB08 Voltage J = 208/240/1/60
Air Dimensional Data RF1T/RF1P Series Unit Dimensions Unit Dimensions & Weights Dimensional Data Model RF1P18 RF1P24 RF1P30 RF1P36 RF1T24 RF1T36 (A) Unit Width In. [mm] 211/2 [546.1] 211/2 [546.1] 241/2 [609.6] 241/2 [609.6] 211/2 [546.1] 241/2 [609.6] (B) Unit Height In. [mm] 36 [914.4] 36 [914.4] 36 [914.4] 36 [914.4] 36 [914.4] 36 [914.4] (C) Unit Depth In. [mm] 17 [431.8] 17 [431.8] 21 [533.4] 21 [533.4] 17 [431.8] 21 [533.4] (D) Return Air Opening Width In. [mm] 20 [508] 20 [508] 23 [584.
Air Dimensional Data RF1T/RF1P Series Unit Dimensions (con’t.) 11/2 & 2 TON [5.28 & 7.03 kW] MODELS [ ] Designates Metric Conversions 6 21/2 & 3 TON [8.79 & 10.
Air Airflow Performance Data RF1T/RF1P Series Airflow Performance Airflow performance data is based on cooling performance with a coil and filter in place. Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the .3 [8 mm] to .
Air Airflow Performance Data RF1T/RF1P Series 208V/240V Airflow Performance Data—RF1P (PSC Motor) Nominal Manufacturer Cooling Recommended Capacity Air-Flow Range Tons [kW] (Min/Max) CFM Blower Size/ Motor Motor Speed HP [W] & from # of Speeds Factory PSC Motor Speed High 1.5 873/438 10X6 1/5 Hp 2 speed dual voltage High Low High 2 1137/764 10X6 1/5 Hp 2 speed dual voltage High Low High 2.
Air Airflow Performance Data RF1T/RF1P Series 208V/240V Airflow Performance Data—RF1T (X-13 (ECM) Motor) Manufacturer Nominal Recommended Cooling Capacity Air-Flow Range Tons [kW] (Min/Max) CFM Blower Size/ Motor Motor Speed HP [W] & from # of Speeds Factory 5 1.5 852/510 5 973/733 5 1145/894 5 1306/1040 5 4 3 10X8 1/2 Hp 2 speed dual voltage 5 3 2 10X6 1/3 Hp 2 speed dual voltage 5 2.
Air Piston Sizing Chart RF1T/RF1P Series Piston Sizing Chart Indoor Unit Factory Piston RF1P1821SPANJA 0.047 RF1P2421SPANJA 0.053 RF1P3024SPANJA 0.061 RF1P3624SPANJA 0.065 10 SEER Rating OD Unit Nominal Tons Refrigerant Orifice Size 13 1.5 R410a 0.047 14 13 12 10 13 14 13 12 10 13 14 13 12 10 13 14 13 12 10 1.5 1.5 1.5 1.5 2 2 2 2 2 2.5 2.5 2.5 2.5 2.5 3 3 3 3 3 R410a R22 R22 R22 R410a R410a R22 R22 R22 R410a R410a R22 R22 R22 R410a R410a R22 R22 R22 0.049 0.049 0.051 0.053 0.053 0.
Air Electrical Data RF1T/RF1P Series RF1P/RF1T Electrical Data – Blower Motor Only – No Electric Heat 1.5 Minimum Circuit Ampacity 3 Maximum Circuit Protector 15 1.5 2.5 3 4 15 15 2 2.5 4 15 4 4 1.6 2.7 3 4 15 15 Model/Nominal Cooling Tons Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps.
Air Accessories RF1T/RF1P Series 16.0 Accessories-Kits-Parts • Drain Pan Over Flow Switch RXHK-A01 is used to detect condensate drain blockage and will shut down the outdoor unit in order to prevent structural damage to the surrounding structures of the air handler. • Bottom Return Conversion Kit RXHK- is used to divert the return air from the factory standard front return to a bottom return.
Air Limited Warranty RF1T/RF1P Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required) ..........
Air 14 Notes RF1T/RF1P Series
Air Notes RF1T/RF1P Series 15
The new degree of comfort.™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 PRINTED IN U.S.A. 12/14 QG FORM NO.