Instructions / Assembly

16
INSTALLATION INSTRUCTIONS
General
Every vent or air intake pipe penetration of a floor
or ceiling should be sealed.
Failure to install and properly vent the water heater
to the outdoors as outlined on "Venting" can result
in unsafe operation.
Long hot water lines should be insulated to
conserve water and energy.
The water heater and water lines should be
protected from exposure to freezing temperatures.
Minimum water heater clearances from
combustible and noncombustible construction are
as follows:
– 1/2 in. (1.3 cm) for sides and front
– 0 in. (0 cm) for rear with support bracket(s)
– 12 in. (30 cm) from the bottom and top
– 0 in. (0 cm) for vent or air intake pipe
NOTICE:
Preferred maintenance clearance is 24 in. (61 cm)
from top, bottom, and front of unit.
12" min.
(300 mm)
12" min.
(300 mm)
0" min.
(0 mm)
1/2" min.
(13 mm)
1/2" min.
(13 mm)
0"
(0 mm)
Sealing Plate
DO NOT install the water heater in areas
prohibited by National Fuel Gas Code in
U.S. installation or CAN/CSA B149.1 in
Canadian installation.
DO NOT install the water heater where it
is subject to vibrations.
DO NOT install the water heater in a
recreational vehicle, boat, or other
watercraft.
DO NOT install the water heater near
vents for heating and cooling unless
a minimum clearance of 4 ft (1.2 m) is
maintained.
Choosing a Location (cont.)