Operating instructions
5
Installing the water heater.
The location chosen for the water heater must take into consideration the following:
Local Installation Regulations
This water heater must be installed in 
accordance with these instructions, local 
codes, utility codes, utility company 
requirements or, in the absence of local 
codes, the latest edition of the National 
Electrical Code. It is available from some 
local libraries or can be purchased from 
the National Fire Protection Association, 
Batterymarch Park, Quincy, MA 02269 as 
booklet ANSI/NFPA 70.
Location
Locate the water heater in a clean dry area 
as near as practical to the area of greatest 
heated water demand. Long un-insulated 
hot water lines can waste energy and 
water. 
Place the water heater in such a manner 
that the thermostat and element access 
panels can be removed to permit inspection 
and servicing such as removal of elements 
or checking controls. 
The water heater and water lines should 
be protected from freezing temperatures. 
Do not install the water heater in outdoor, 
unprotected areas.
Make certain the floor underneath 
the water heater is strong enough to 
sufficiently support the weight of the 
water heater once it is filled with water.
CAUTION: The water heater should 
not be located in an area where leakage 
of the tank or connections will result 
in damage to the area adjacent to it or 
to lower floors of the structure. Where 
such areas cannot be avoided, it is 
recommended that a suitable catch pan, 
adequately drained, be installed under 
the water heater.
A— Diameter of water 
heater plus 2″ min.
B— Maximum  2″
NOTICE: Auxiliary catch pan MUST conform to local codes.
Catch Pan Kits are available from the store where the water 
heater was purchased, or any water heater distributor.
B
A
To open drain, line 
should be at least 3/4″ ID 
and pitched for proper 
drainage.
Inspect Shipment
Inspect the water heater for possible damage. Check the markings on the rating plate 
of the water heater to be certain the power supply corresponds to the water heater 
requirements.
!