Specification Sheet
Air
Physical Data & Specifications
RGTM Series
4
MODEL NUMBERS RGTM-06
*
MAES RGTM-09
*
ZAJS**
HIGH FIRE INPUT BTU/HR [kW] ➀
60,000 [17.58] 90,000 [26.38]
LOW FIRE INPUT BTU/HR [kW] ➁
42,000 [12.31] 63,000 [18.46]
HIGH ALTITUDE INPUT 8000' ➁
40,800 [11.96] 61,200 [17.94]
HIGH ALTITUDE OUTPUT
AT 8000' (HIGH FIRE) [kW] ➁
37,944 [11.12] 56,916 [16.69]
BLOWER (D x W)
[mm]
11 x 7
[279 x 178]
12 x 11
[305 x 279]
MOTOR H.P. [W]–
SPEEDS–TYPE
1
/2 [373] VAR.
SPEED
1 [746] VAR.
SPEED
MOTOR FULL LOAD AMPS 8.7 12
MINIMUM EXT. STATIC
PRESSURE (IN. W.C.) [kPa]
.12 [.029] .15 [.037]
HIGH COOLING CFM @ .8"
[.124 kPa] W.C. E.S.P. [L/s] ➃
A = 1200 A = 1900
C = 800 C = 1400
TEMPERATURE RISE-HIGH FIRE
RANGE IN DEGREES °F [°C]
35-65
[19.4-36.1]
30-60
[16.7-33.3]
APPROX. SHIPPING WEIGHT
(LBS.) [kg]
123
[56.0]
148
[67.3]
AFUE ➂
95.0% 95.0%
RETURN AIR CABINETS (OPT.)
RXGR-
FILTER SIZE
[mm]
C17B
(2) 12" x 16"
[305 x 406]
C21B
(2) 12" x 16"
[305 x 406]
STANDARD, HIGH VELOCITY
PERMANENT FILTER (IN.)
15
3
/4 x 25 x 1 19
1
/4 x 25 x 1
HEATING CAPACITY BTU/HR [kW] 56,000 [16.41] 84,000 [24.62]
TEMPERATURE RISE-LOW FIRE
RANGE IN DEGREES °F [°C]
30-60
[16.7-33.3]
25-55
[13.9-30.6]
MAXIMUM EXT. STATIC
PRESSURE (IN. W.C.) [kPa]
.80 [0.2] .80 [0.2]
RGTM-07
*
RBGS
15
3
/4 x 25 x 1
75,000 [21.98]
52,500 [15.39]
51,000 [14.95]
70,000 [20.51]
47,430 [13.90]
11 x 10
[297 x 254]
3
/4 [559] VAR.
SPEED
25-55
[13.9-30.6]
12
.12 [.029]
.80 [0.2]
A = 1600
C = 1200
30-60
[16.7-33.3]
139
[63.2]
95.0%
C21B
(2) 12" x 16"
[305 x 406]
RGTM-10
*
RBJS
105,000 [30.77]
22
3
/4 x 25 x 1
73,500 [21.54]
71,400 [20.93]
66,402 [19.46]
97,000 [28.43]
11 x 10
[297 x 254]
1 [746] VAR.
SPEED
12
30-60
[16.7-33.3]
.20 [.049]
.80 [0.2]
A = 2000
C = 1400
35-65
[19.4-36.1]
165
[75]
95.0%
C29B
(2) 14" x 16"
[609 x 406]
B = 1400 B = 1600B = 1000 B = 1600
D = 1000 D = 1200
D = 600
D = 1200
A = 1200
C = 900
A = 1500
LOW COOLING CFM @ .8"
[.124 kPa] W.C. E.S.P. [L/s] ➃
A = 900
C = 1050
A = 1500
C = 600 C = 1050
B = 1050 B = 1200B = 750 B = 1200
D = 750 D = 900
D = 450
D = 900
MAX. OUTLET AIR TEMPERATURE 170 170 165 180
1100
[517]
LOW HEATING CFM @ 0.2"
[0.049 kPa] W.C. E.S.P. [L/s]*
800
[376]
1350
[635]
1460
[686]
1408
[662]
HIGH HEATING CFM @ 0.2"
[0.049 kPa] W.C. E.S.P. [L/s]*
1048
[493]
1660
[780]
1752
[823]
NOTES: All models are 115V, 60HZ, 1 phase. Gas connection size for all models is
1
/2" [13 mm] N.P.T.
➀ See Conversion Kit Index Form for high altitude derate.
➁ Canadian installations only.
➂ In accordance with D.O.E. test procedures.
➃ CFM is Nominal Value. Positive airflow adjustments will increase the Heating CFM—
See Installation Instructions.
*E=Standard
*N=NOx Models
**12 x 11 Housing, 11 x 10 Wheel
[ ] Designates Metric Conversions
WARNING: Some heating airflow values may be higher
than those required for cooling. Be sure to size duct
systems for highest possible airflow value.
Physical Data and Specifications—Downflow/Horizontal Models
U.S. and Canadian Models