Specification Sheet

Air
Physical Data & Specifications
RGTM Series
4
MODEL NUMBERS RGTM-06
*
MAES RGTM-09
*
ZAJS**
HIGH FIRE INPUT BTU/HR [kW]
60,000 [17.58] 90,000 [26.38]
LOW FIRE INPUT BTU/HR [kW]
42,000 [12.31] 63,000 [18.46]
HIGH ALTITUDE INPUT 8000'
40,800 [11.96] 61,200 [17.94]
HIGH ALTITUDE OUTPUT
AT 8000' (HIGH FIRE) [kW]
37,944 [11.12] 56,916 [16.69]
BLOWER (D x W)
[mm]
11 x 7
[279 x 178]
12 x 11
[305 x 279]
MOTOR H.P. [W]–
SPEEDS–TYPE
1
/2 [373] VAR.
SPEED
1 [746] VAR.
SPEED
MOTOR FULL LOAD AMPS 8.7 12
MINIMUM EXT. STATIC
PRESSURE (IN. W.C.) [kPa]
.12 [.029] .15 [.037]
HIGH COOLING CFM @ .8"
[.124 kPa] W.C. E.S.P. [L/s]
A = 1200 A = 1900
C = 800 C = 1400
TEMPERATURE RISE-HIGH FIRE
RANGE IN DEGREES °F [°C]
35-65
[19.4-36.1]
30-60
[16.7-33.3]
APPROX. SHIPPING WEIGHT
(LBS.) [kg]
123
[56.0]
148
[67.3]
AFUE
95.0% 95.0%
RETURN AIR CABINETS (OPT.)
RXGR-
FILTER SIZE
[mm]
C17B
(2) 12" x 16"
[305 x 406]
C21B
(2) 12" x 16"
[305 x 406]
STANDARD, HIGH VELOCITY
PERMANENT FILTER (IN.)
15
3
/4 x 25 x 1 19
1
/4 x 25 x 1
HEATING CAPACITY BTU/HR [kW] 56,000 [16.41] 84,000 [24.62]
TEMPERATURE RISE-LOW FIRE
RANGE IN DEGREES °F [°C]
30-60
[16.7-33.3]
25-55
[13.9-30.6]
MAXIMUM EXT. STATIC
PRESSURE (IN. W.C.) [kPa]
.80 [0.2] .80 [0.2]
RGTM-07
*
RBGS
15
3
/4 x 25 x 1
75,000 [21.98]
52,500 [15.39]
51,000 [14.95]
70,000 [20.51]
47,430 [13.90]
11 x 10
[297 x 254]
3
/4 [559] VAR.
SPEED
25-55
[13.9-30.6]
12
.12 [.029]
.80 [0.2]
A = 1600
C = 1200
30-60
[16.7-33.3]
139
[63.2]
95.0%
C21B
(2) 12" x 16"
[305 x 406]
RGTM-10
*
RBJS
105,000 [30.77]
22
3
/4 x 25 x 1
73,500 [21.54]
71,400 [20.93]
66,402 [19.46]
97,000 [28.43]
11 x 10
[297 x 254]
1 [746] VAR.
SPEED
12
30-60
[16.7-33.3]
.20 [.049]
.80 [0.2]
A = 2000
C = 1400
35-65
[19.4-36.1]
165
[75]
95.0%
C29B
(2) 14" x 16"
[609 x 406]
B = 1400 B = 1600B = 1000 B = 1600
D = 1000 D = 1200
D = 600
D = 1200
A = 1200
C = 900
A = 1500
LOW COOLING CFM @ .8"
[.124 kPa] W.C. E.S.P. [L/s]
A = 900
C = 1050
A = 1500
C = 600 C = 1050
B = 1050 B = 1200B = 750 B = 1200
D = 750 D = 900
D = 450
D = 900
MAX. OUTLET AIR TEMPERATURE 170 170 165 180
1100
[517]
LOW HEATING CFM @ 0.2"
[0.049 kPa] W.C. E.S.P. [L/s]*
800
[376]
1350
[635]
1460
[686]
1408
[662]
HIGH HEATING CFM @ 0.2"
[0.049 kPa] W.C. E.S.P. [L/s]*
1048
[493]
1660
[780]
1752
[823]
NOTES: All models are 115V, 60HZ, 1 phase. Gas connection size for all models is
1
/2" [13 mm] N.P.T.
See Conversion Kit Index Form for high altitude derate.
Canadian installations only.
In accordance with D.O.E. test procedures.
CFM is Nominal Value. Positive airflow adjustments will increase the Heating CFM—
See Installation Instructions.
*E=Standard
*N=NOx Models
**12 x 11 Housing, 11 x 10 Wheel
[ ] Designates Metric Conversions
WARNING: Some heating airflow values may be higher
than those required for cooling. Be sure to size duct
systems for highest possible airflow value.
Physical Data and Specifications—Downflow/Horizontal Models
U.S. and Canadian Models