Submittal Sheet

UNIT DATA
COOLING PERFORMANCE
EFFICIENCY ..................................
_______
SEER
TOTAL CAPACITY ....................
_______
MBH [kW]
SENSIBLE CAPACITY ..............
_______
MBH [kW]
OUTDOOR DESIGN TEMP. ........
_______
°F [°C] DB
TEMP. OF AIR ENTERING
EVAPORATOR COIL ..............
_______
°F [°C] DB
_______
°F [°C] WB
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ..................
_______
CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT........................................
_______
IWC
MOTOR RATING ..........................
_______
HP [W]
ELECTRICAL DATA
POWER SUPPLY ............................
__________ Hz
MINIMUM WIRE SIZE ......................
_______
AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER ............
_______
AMPS
CLEARANCES
ACCESS SIDE 24" [609.6 mm]
AIR INLETS 6" [152 mm]
ABOVE UNIT 60" [1524 mm]
(-)APM- JAZ SERIES – AIR CONDITIONERS
EFFICIENCIES TO 16 SEER/13 EER
NOMINAL SIZES 1.5-5 TONS [5.28-17.6 kW]
JOB NAME UNIT MODEL NO.
CONTRACTOR COIL MODEL NO.
ENGINEER AIR HANDLER MODEL NO.
SUBMITTED FOR APPROVAL RECORD LOCATION
DATE ORDER NO.
(IN CERTAIN MATCHED SYSTEMS)
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with
appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
FORM NO. X33-1408
Supersedes Form No. X33-1277
FEATURES FOR (-)APM- JAZ SERIES
• R410-A Refrigerant
• High Efficiency
• Scroll Compressor
All refrigerant connections are on the exterior of the unit, located close to the
ground for neat appearing installations.
Powder painted galvanized steel cabinet. The full wrap-around louvered grille
protects the coil from damage.
Copper tube—aluminum fin coils are used on all models.
The control box is located in the top corner of the cabinet providing for easy
access through a service panel.
• Service valves are standard on all models.
• Power and control wiring are kept separate.
Separate compressor compartment for easy service access.
Drawn, painted base pan for extra corrosion resistance and sound reduction.
The automatic high and low pressure controls are standard on the (-)APM
model.
The filter drier is standard on all models.
• Certified and rated under AHRI Standard 210.
• U.L. and cUL listed.
• Factory limited warranty on all parts as follows:
Conditional Parts (Registration Required) ....................................Ten (10) Years
FIELD INSTALLED ACCESSORIES
Low Ambient Control ........................................................................................
Compressor Time Delay Control ......................................................................
Hard Start Components ....................................................................................
Compressor Crankcase Heater (CCH) ..............................................................