Specification Sheet

4 Rheem Manufacturing Company
2414 RXHH-A01
3617/3621 RXHH-A03
4821/4824 RXHH-A04
Coil Model Horizontal Adapter Kit Model No.
2417 RXHH-A02
6024 RXHH-A05
Table 4: Horizontal Adapter Kit Model No.
Accessories
• PLENUM ADAPTER ACCESSORY
RXBA-AE
This plenum adapter accessory is for use with the 24
1
/2" wide
cased indoor cooling and heat pump coils. This allows a 24
1
/2"
wide cased coil to be installed on a 28" wide oil furnace. This is a
field-installed accessory only.
• RXBA-AC (Upflow/Horizontal)
These plenum adapter accessories are for use when a cooling
coil is matched with a gas furnace of one smaller size.
• HORIZONTAL ADAPTER KIT RXHH (See Figure 2)
This horizontal adapter kit is used to convert a upflow or downflow
coil for a horizontal application. See Table 4 to order the proper
horizontal adapter kit.
Table 3: Coil Application
Coils can be matched to heating products as listed in table below.
Coil Model
RCFA/RCFL
Oil Gas
2414
2417
3617
— 14 [356]
2417
3617
21 [533]
17
1
/
2
[444]
14 [356]
21 [533]
17
1
/
2
[444]
Furnace Width
(In.) (mm)
24
1
/
2
[622]
21 [533]
21 [533]
3621
4821
24
1
/
2
[622]
4824
6024
AIR FLOW
HORIZONTAL-DUAL
DIRECTION
FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION
RXBC—D14I
INSULATION
I = Insulated
Blank = Uninsulated
CABINET WIDTH
14 = 14" [356 mm]
17 = 17.5" [444 mm]
21 = 21" [533 mm]
24 = 24.5" [622 mm]
DESIGN SERIES
COIL CASING
BLOWER UNIT
ACCESSORY
RHEEM
Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings
RXBC-D17AI 17
1
/
2
[445] 20 [508] 18 [8] 16
1
/
2
[419]
RXBC-D21BI 21 [533] 28 [711] 27 [12] 20 [508]
RXBC-D24AI 24
1
/
2
[622] 32
1
/
2
[826]
Model
Number
34 [16]
Width
(in.) [mm]
23
1
/
2
[597]
Height
(in.) [mm]
Depth
(in.)
[mm]
Unit Weight
Supply Air/Return
Air Openings
RXBC-D21AI 21 [533] 20 [508] 20 [9] 20 [508]
19
31
/
32
[508]
RXBC-D14AI 14 [356] 23
3
/
16
[589]
21
5
/
8
[549]
19 [9] 13 [330]
23 [10]
23 [10]
36 [17]
44 [20]
26 [12]
Ship. Wt.
(lbs.) [Kg.]
Depth
(in.)
[mm]
Weight
(lbs.) [Kg.]
Width
(in.) [mm]
[ ] Designates Metric Conversions
• INDOOR COIL CASING- RXBC (See Table 5)
HORIZONTAL ADAPTER KIT (RXHH-)
*Note: Due to the proximity of the drain pan to the high temperature oil furnace drain, horizontal left application is not permitted on all oil furnaces.