OUTLET TEMPERATURE COMPENSATION ADJUSTMENT – 886 SERIES 
The maximum outlet temperature of an 886 series water heater may be adjusted to compensate for 
temperature losses in the pipe work between the water heater outlet and sanitary fixtures. 
 Warnings 
•  After adjustment the water temperature MUST NOT exceed 50°C from the first tap in the hot water pipe 
work after the water heater used for personal hygiene purposes, such as in a bathroom or ensuite. 
•  If there is a tap, such as a kitchen or laundry tap, in the hot water pipe work between the water heater 
and the first tap used for personal hygiene purposes, then it is possible for a water temperature to be 
delivered from that tap of up to 3°C higher than the setting shown on the controller. 
It is necessary to have the electrical supply to the water heater switched on during stages of the outlet 
temperature compensation adjustment procedure. 
 Warnings 
•  The removal of the front panel will expose 240 volt wiring. Take care not to touch wiring terminals. The 
adjustment must be carried out by a qualified person. 
•  This procedure will involve the adjustment of dip switches. Adjustment of a dip switch should only be 
made with an insulated tool. 
This procedure cannot be conducted with a temperature 
controller connected to the water heater. Any temperature 
controller(s) connected to the water heater must be 
disconnected prior to the commencement of this procedure. 
Disconnecting a Temperature Controller(s) 
To disconnect the temperature controller(s): 
1.  Switch off the electrical supply at the power outlet to the 
water heater. 
2.  Unscrew and gently remove the electrical cover from the 
underside of the water heater. 
3.  Loosen the terminal screws to release the cables. 
4.  Withdraw the cables from the terminals and cable holder 
notches, ensuring they are well clear of the terminals. 
Note: The preset outlet temperature setting of this water 
heater must be set at 50°C prior to the commencement of 
this procedure. Refer to “To Check or Adjust the Outlet 
Temperature Setting” on page 67. 
Outlet Temperature Adjustment 
To adjust the outlet temperature: 
1.  Switch on the electrical supply at the power outlet to the water heater. 
2.  Locate the first hot tap in the hot water pipe work after the water heater used for personal hygiene 
purposes. 
3.  Turn on the hot tap. 
4.  Using a thermometer, measure the temperature of the water from the tap, until the temperature stops 
increasing. 
If the water temperature is below 50°C the maximum outlet temperature of the water heater can be 
adjusted upwards. 