Operating instructions

COMMISSIONING
66
PRESET OUTLET TEMPERATURE SETTING
The factory preset outlet temperature setting of the water heater is:
884 series 60°C – AU, 55°C – NZ
886 series 50°C
If a Deluxe controller is connected to the water heater, this will override the preset outlet temperature setting
and the maximum temperature setting will be:
Maximum Outlet Temperature Setting 884 series 886 series
Kitchen controller connected 60°C – AU, 55°C – NZ 50°C
Bathroom controller only connected 50°C 50°C
It is usually not necessary to check or adjust the factory preset outlet temperature setting of the water heater,
unless the customer has a particular requirement for this to be done or it is to be installed as an in-series gas
booster to a solar water heater.
Gas Booster for a Solar Water Heater
Note: AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in
potable water. When this water heater is used as an in-series gas booster to a solar water heater, it can
satisfy this AS 3498 requirement provided it is energised, the booster preset outlet temperature setting is
70°C or higher and a remote temperature controller is not used.
It will be necessary to check and if required to adjust the preset outlet temperature setting of the continuous
flow water heater when:
it is installed as an in-series gas booster to a solar water heater
it is an existing continuous flow water heater and a solar water heater is then installed.
Notes:
Consideration must be given to the delivery temperature to any ablution and public areas such as a
bathroom, ensuite or public amenities. Refer to “Hot Water Delivery” on page 38 and to “Schematics of
Two Temperature Zones Using A Temperature Limiting Device” on page 39.
The 886 series water heater, marked “THIS APPLIANCE DELIVERS WATER NOT EXCEEDING 50°C
IN ACCORDANCE WITH AS 3498” on the front panel, must not be installed as an in-series gas booster
to a solar water heater, as water temperature greater than 50°C can be delivered from the water heater
contravening its compliance to AS 3498.