CONNECTIONS – ELECTRICAL 
All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the 
Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements. 
 Warning: Temperature controllers must not be fitted to this water heater (884 series) if it is installed as 
an in-series gas booster with a solar water heater or if a Water Star water heater is installed, because water 
at a temperature much higher than the controller setting can be delivered. If a solar or Water Star water 
heater is installed to an existing water heater installation, then all controllers must be disconnected and 
removed. 
The water heater is supplied with a 1.8 metre lead and plug and requires a weatherproof 240 V 50 Hz 
general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear of 
the flue exhaust, draining water, gas supply pipe and water connections. 
The power consumption of the water heater is: 
Component 
Power 
consumption 
Comments 
Gas water heater  80 Watts  024 – Burner on, anti frost device inactive 
  175 Watts  024 – Burner on, anti frost device active 
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be 
used to supply power to the water heater. 